Thyroid Shields versus z-Axis Automatic Tube Current Modulation for Dose Reduction at Neck CT

2008· article· en· W2166789772 on OpenAlexaff
David A. Leswick, Megan M. Hunt, Steven T. Webster, D. Fladeland

Bibliographic record

VenueRadiology · 2008
Typearticle
Languageen
FieldMedicine
TopicRadiation Dose and Imaging
Canadian institutionsUniversity of SaskatchewanRoyal University Hospital
Fundersnot available
KeywordsMedicineNuclear medicineHounsfield scaleImaging phantomThyroidThyroid nodulesThyroid cancerRadiologyComputed tomography

Abstract

fetched live from OpenAlex

PURPOSE: To assess the effectiveness of in-plane bismuth thyroid shields and a z-axis automatic tube current modulation (ATCM) technique with respect to dose reduction and image noise in the thyroid and other regional tissues during neck computed tomography (CT). MATERIALS AND METHODS: Because this was a phantom study, neither institutional review board approval nor HIPAA compliance was required. A female phantom, thyroid shields, and an eight-section CT scanner were used. Radiation dose was measured by using thermoluminescent dosimetry (TLD) chips placed in the phantom's thyroid, cervical bone marrow, and soft tissues. Scans were performed by using fixed tube current and a z-axis ATCM technique with and without shields. Image noise was quantified as the standard deviation of the attenuation value (in Hounsfield units) on CT images. RESULTS: Thyroid dose was 76.9 mGy with an unshielded fixed tube current technique. Use of shields and ATCM reduced this dose to 44.7 mGy (42% reduction, P < .001) and 17.0 mGy (78% reduction, P < .001), respectively. The combination of shields and ATCM further reduced this dose to between 11.9 and 12.9 mGy (83%-85% reduction, P < .001), depending on the shield's presence in the scout scan. ATCM resulted in minimized tube current throughout the neck, which reduced dose-length product across the entire scan volume by 60% (926 vs 368 mGy . cm). Thyroid bed noise was lowest (3.9 HU) during the fixed tube current technique without shields, with noise slightly higher (6.9 HU) with the unshielded ATCM technique (P < .001). Thyroid image noise was markedly higher when using shields (P < .001), with noise measuring between 74 and 113 HU for fixed tube current and ATCM scans. CONCLUSION: z-Axis ATCM is more effective than shields at reducing thyroid radiation dose during neck CT. Shields combined with ATCM slightly further reduces dose; however, this is associated with higher image noise.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.431
Threshold uncertainty score0.419

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.041
GPT teacher head0.312
Teacher spread0.272 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations57
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueRadiologySame topicRadiation Dose and ImagingFrench-language works237,207