MétaCan
Menu
Back to cohort
Record W2166821346 · doi:10.1002/ccd.25005

Three‐dimensional multidetector computed tomography versus conventional 2‐dimensional transesophageal echocardiography for annular sizing in transcatheter aortic valve replacement: Influence on postprocedural paravalvular aortic regurgitation

2013· article· en· W2166821346 on OpenAlexaff
Nicolaj C. Hansson, Leif Thuesen, Vibeke E. Hjortdal, Jonathon Leipsic, Henning Andersen, Steen Hvitfeldt Poulsen, John G. Webb, Evald Høj Christiansen, Lars Ege Rasmussen, Lars Romer Krusell, Kim Terp, Kaj Erik Klaaborg, Mariann Tang, Jens Flensted Lassen, Hans Erik Bøtker, Bjarne Linde Nørgaard

Bibliographic record

VenueCatheterization and Cardiovascular Interventions · 2013
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsSt. Paul's HospitalUniversity of British Columbia
FundersNovo Nordisk Fonden
KeywordsMedicineRegurgitation (circulation)Multidetector computed tomographyCardiologyInternal medicineRadiologyValve replacementAortic valveComputed tomographyStenosis

Abstract

fetched live from OpenAlex

OBJECTIVES: In transcatheter aortic valve replacement (TAVR), the influence of aortic annular assessment with either multidetector computed tomography (MDCT) or conventional transesophageal echocardiography (TEE) on the incidence of postprocedural paravalvular aortic regurgitation (PAR) was evaluated. BACKGROUND: PAR remains a major limitation in TAVR. Appropriate selection of transcatheter heart valve (THV) size is crucial to prevent PAR. METHODS: Outcomes following TAVR with a balloon-expandable THV were compared in two retrospective cohorts identified according to whether THV size selection was based on TEE (study group 1, n = 80) or MDCT (study group 2, n = 58). RESULTS: The two study groups were comparable with regard to baseline clinical, risk score, and echocardiographic characteristics. The incidence of moderate/severe PAR was lower in study group 2 than in group 1, 8.6% versus 28.8% (P < 0.01). The difference between the THV nominal diameter and MDCT annular diameter was predictive of moderate/severe PAR (AUC 0.84; 95% CI: 0.72-0.92). Neither age, gender, body mass index, annular eccentricity index, aortic valve calcification nor the difference between the THV diameter and the TEE annular diameter predicted postprocedural PAR. Increased THV oversizing relative to the MDCT mean annular diameter was associated with reduced severity of PAR. No difference in perprocedural complications between two study groups was observed. CONCLUSION: MDCT-based annular sizing in TAVR significantly reduces postprocedural PAR, and THV oversizing appears pivotal in this aspect. Further delineation of the optimal degree of THV oversizing is needed.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Meta-epidemiology (broad)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.253
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.010
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.295
Teacher spread0.276 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations44
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueCatheterization and Cardiovascular InterventionsSame topicCardiac Valve Diseases and TreatmentsFrench-language works237,207