MétaCan
Menu
Back to cohort
Record W2168637508 · doi:10.3171/foc.2006.20.5.3

The BION devices: injectable interfaces with peripheral nerves and muscles

2006· review· en· W2168637508 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

fundA Canadian funder is recorded on the work.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueNeurosurgical FOCUS · 2006
Typereview
Languageen
FieldEngineering
TopicMuscle activation and electromyography studies
Canadian institutionsnot available
FundersNational Institute of Biomedical Imaging and BioengineeringNational Rehabilitation CenterQueen's UniversityNational Institutes of HealthNational Science Foundation
KeywordsMedicinePhysical medicine and rehabilitationMuscle contractureFunctional electrical stimulationStimulationRehabilitationPhysical therapySubluxationSurgeryInternal medicine

Abstract

fetched live from OpenAlex

OBJECT: The purpose of this study was to describe a novel technology for implantable neuromuscular stimulation to treat complications of paralysis and disuse atrophy, including shoulder subluxation, hand contractures, drop foot, and osteoarthritis. The authors review the results so far of several pilot clinical studies of these muscle stimulation devices. METHODS: Miniature wireless stimulators received power and individually addressed command signals from an external radiofrequency transmission coil. One or more implants were injected through a 12-gauge hypodermic insertion tool into muscles or adjacent to motor nerves, where they provided the means to activate the muscles in any desired pattern of intensity and frequency. Randomized controlled studies in small numbers of patients are underway to identify efficacy, acceptability, best methods of practice, and any design changes that may be required to improve the technology. Fifty patients have been enrolled in five studies; 35 patients have undergone implantation of a total of 79 BION1 devices. Comparisons with surface stimulation in patients who have suffered a stroke with shoulder subluxation and hand contractures show similar improvements in objective measures of efficacy but higher comfort levels for stimulation by implants. CONCLUSIONS: Injected microstimulators represent a promising new class of technology for the rehabilitation of patients with upper motor neuropathies. As the technology evolves, practitioners may be able to use it to facilitate functional reanimation of paralyzed limbs.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.998
Threshold uncertainty score0.822

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.245
Teacher spread0.227 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it