Psychopathology in Patients with ICDs over Time: Results of a Prospective Study

2009· article· en· W2170077038 on OpenAlexaff
Suraj Kapa, Debra Rotondi-Trevisan, Z. Mariano, Theresa Aves, Jane Irvine, Paul Dorian, David L. Hayes

Bibliographic record

VenuePacing and Clinical Electrophysiology · 2009
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsSt. Michael's HospitalYork University
Fundersnot available
KeywordsMedicinePsychopathologyHospital Anxiety and Depression ScaleAnxietyDepression (economics)Implantable cardioverter-defibrillatorProspective cohort studyQuality of life (healthcare)Psychological interventionInternal medicinePsychiatry

Abstract

fetched live from OpenAlex

INTRODUCTION: The effects of implantable cardioverter defibrillators (ICDs) and ICD shocks on psychological state have previously been studied. However, it is still unclear how health-related quality-of-life changes over time using standardized assessments. We sought to characterize the effects of ICDs and ICD shocks on psychological outcomes. METHODS: Three hundred-eight patients receiving ICDs were prospectively identified. Baseline QOL assessments including standardized psychological surveys [Hospital Anxiety and Depression Scale (HADS), Impact of Events Scale-Revised (IES-R), and Short Form 36 Health Survey (SF-36)] were obtained within 2 months of device implantation and at 6 and 12 months, respectively. Outcomes including ICD shocks were followed over the 12-month study period. RESULTS: The number of patients meeting criteria for anxiety or posttraumatic stress disorder (PTSD) at baseline (78/223, 35%) was higher than at 6 (34/223, 15%) or 12 (34/223, 15%) months (P < 0.01). There was a significant improvement over time in HADS (P < 0.001) and IES-R (PTSD) scores (P < 0.001). Amongst the 20 patients who received ICD shocks, no significant differences were observed in IES-R, SF-36, or HADS scores when compared with those who did not receive shocks at any time point. Patients who experienced electrical storms (N = 5) had significantly higher baseline PTSD scores (29.6 +/- 11.4 vs 14.6 +/- 11.6, P < 0.01). CONCLUSIONS: Patients receiving ICDs have significant rates of baseline psychopathology after implantation. However, psychological assessment scores tend to improve with time. ICD shocks do not appear to significantly impact psychological state. These results suggest the importance of close screening and referral for possible psychopathology in patients receiving ICDs, especially in the peri-implant period.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.019
Threshold uncertainty score0.341

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.327
Teacher spread0.319 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations113
Published2009
Admission routes1
Has abstractyes

Explore more

Same venuePacing and Clinical ElectrophysiologySame topicCardiac pacing and defibrillation studiesFrench-language works237,207