MétaCan
Menu
Back to cohort
Record W2170681857 · doi:10.1109/tuffc.2015.007134

Nonlocal means filter-based speckle tracking

2015· article· en· W2170681857 on OpenAlexafffund
Narges Afsham, Abtin Rasoulian, Mohammad Najafi, Purang Abolmaesumi, Robert Rohling

Bibliographic record

VenueIEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · 2015
Typearticle
Languageen
FieldMedicine
TopicUltrasound Imaging and Elastography
Canadian institutionsUniversity of British Columbia
FundersCanadian Institutes of Health Research
KeywordsSpeckle patternFilter (signal processing)Speckle noiseComputer scienceComputer visionArtificial intelligenceTracking (education)Displacement (psychology)Rician fadingImage planeAlgorithmMathematicsImage (mathematics)

Abstract

fetched live from OpenAlex

The objective of sensorless freehand 3-D ultrasound imaging is to eliminate the need for additional tracking hardware and reduce cost and complexity. However, the accuracy of current out-of-plane pose estimation is main obstacle for full 6-degree-of-freedom (DoF) tracking. We propose a new filter-based speckle tracking framework to increase the accuracy of out-of-plane displacement estimation. In this framework, we use the displacement estimation not only for the specific speckle pattern, but for the entire image. We develop a nonlocal means (NLM) filter based on a probabilistic normal variance mixture model of ultrasound, known as Rician-inverse Gaussian (RiIG). To aggregate the local displacement estimations, Stein's unbiased risk estimate (SURE) is used as a quality measure of the estimations. We derive an explicit analytical form of SURE for the RiIG model and use it as a weight factor. The proposed filter-based speckle tracking framework is formulated and evaluated for three commonly used noise models, including the RiIG model. The out-of-plane estimations are compared with our previously proposed model-based algorithm in a set of ex vivo experiments for different tissue types. We show that the proposed RiIG filter-based method is more accurate and less tissue-dependent than the other methods. The proposed method is also evaluated in vivo on the spines of five different subjects to assess the feasibility of a clinical application. The 6-DoF transform parameters are estimated and compared with the electromagnetic tracker measurements. The results show higher tracking accuracy for typical small lateral displacements and tilt rotations between image pairs.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.003
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.023
GPT teacher head0.250
Teacher spread0.227 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations18
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueIEEE Transactions on Ultrasonics Ferroelectrics and Frequency ControlSame topicUltrasound Imaging and ElastographyFrench-language works237,207