MétaCan
Menu
Back to cohort
Record W2171858767 · doi:10.1016/j.carj.2009.10.013

Measurement of Carotid Stenosis on Computed Tomographic Angiography: Reliability Depends on Postprocessing Technique

2010· article· en· W2171858767 on OpenAlexaff
Peter Howard, Eric Bartlett, Sean Symons, Allan J. Fox, Richard I. Aviv

Bibliographic record

VenueCanadian Association of Radiologists Journal · 2010
Typearticle
Languageen
FieldMedicine
TopicCerebrovascular and Carotid Artery Diseases
Canadian institutionsPrincess Margaret Cancer CentreHealth Sciences CentreUniversity of TorontoSunnybrook Health Science Centre
Fundersnot available
KeywordsStenosisMedicineCarotid endarterectomyRadiologyAngiographyNuclear medicineOcclusionUltrasoundSurgery

Abstract

fetched live from OpenAlex

PURPOSE: We previously demonstrated the validity of axial source (AxS) image quantification of computed tomographic angiography (CTA) visualized carotid stenosis. There is concern that AxS images may not accurately measure stenosis in patients with obliquely orientated stenosis and that measurements on axial oblique (AxO) multiplanar reformats (MPR), maximum intensity projections (MIP) images, or Doppler ultrasound (DUS) are superior. We tested the performance of AxS images against AxO MPRs, MIPs, and DUS techniques for stenosis quantification. METHODS: A total of 120 consecutive patients with CTA and DUS detected carotid disease were enrolled; carotids with occlusion, near occlusion, or stenosis <40% were excluded. Proximal and distal carotid diameters and North American Symptomatic Carotid Endarterectomy Trial (NASCET) style ratios were measured independently by 2 neuroradiologists on AxS, AxO, and MIP images on separate occasions in a blinded protocol. Intra- and interobserver agreements were determined for all measurements. The performance of different image types to identify > or =70% stenosis was assessed against a NASCET-style reference standard. RESULTS: Intra- and interobserver reliabilities for stenosis measurements were higher for both AxS (interclass correlation coefficients [ICC], 0.87-0.93 and 0.84-0.89) and AxO images (ICCs, 0.82-0.89 and 0.86-0.92) than for MIPs (ICCs, 0.66-0.86 and 0.79-0.82), respectively. Intra- and interobserver agreements on the NASCET ratio tended to be lower than proximal stenosis measurements. AxS and AxO image proximal stenosis measurements most accurately distinguished patients with > or =70% stenosis (0.90), followed by DUS (0.83) and MIP images (0.76). CONCLUSIONS: A single AxS image stenosis measurement was highly reproducible and accurate in the estimation of carotid stenosis, which precluded the need for AxO MPRs.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.011
metaresearch head score (Gemma)0.037
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.011
Threshold uncertainty score0.058

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0110.037
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0000.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.232
Teacher spread0.222 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueCanadian Association of Radiologists JournalSame topicCerebrovascular and Carotid Artery DiseasesFrench-language works237,207