MétaCan
Menu
Back to cohort
Record W2196354034 · doi:10.1039/c5an02239h

Highly CO<sub>2</sub>sensitive extruded fluorescent plastic indicator film based on HPTS

2015· article· en· W2196354034 on OpenAlexfundno aff
Andrew Mills, Dilidaer Yusufu

Bibliographic record

VenueThe Analyst · 2015
Typearticle
Languageen
FieldChemical Engineering
TopicAnalytical Chemistry and Sensors
Canadian institutionsnot available
FundersEngineering and Physical Sciences Research CouncilQueen's UniversityDepartment of Agriculture, Food and the Marine, IrelandQueen's University Belfast
KeywordsFluorescenceMaterials scienceAnalytical Chemistry (journal)ChemistryEnvironmental chemistryOpticsPhysics

Abstract

fetched live from OpenAlex

Highly-sensitive optical fluorescent extruded plastic films are reported for the detection of gaseous and dissolved CO2. The pH-sensitive fluorescent dye used is 8-hydroxypyrene-1,3,6-trisulfonic acid trisodium salt (HPTS, PTS(-)) coated on the surface of hydrophilic fumed silica and the base is tetrabutylammonium hydroxide (TBAH). The above components are used to create an HPTS pigment (i.e. HPTS/SiO2/TBAH) with a high CO2 sensitivity (%CO2 (S = 1/2) = 0.16%) and fast 50% response (t50↓) = 2 s and recovery (t50↑) = 5 s times. Highly CO2-sensitive plastic films are then fabricated, via the extrusion of the HPTS pigment powder in low-density polyethylene (LDPE). As with the HPTS-pigment, the luminescence intensity (at 515 nm) and absorbance (at 475 nm) of the HPTS plastic film decreases as the %CO2 in the ambient gas phase increases. The HPTS plastic film exhibits a high CO2 sensitivity, %CO2 (S = 1/2), of 0.29%, but a response time <2 min and recovery time <40 min, which is slower than that of the HPTS pigment. The HPTS plastic film is very stable under ambient conditions, (with a shelf life >six month when stored in the dark but under otherwise ambient conditions). Moreover, the HPTS-LDPE film is stable in water, salt solution and even in acid (pH = 2), and in each of these media it can be used to detect dissolved CO2.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.206
Threshold uncertainty score0.992

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.231
Teacher spread0.214 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations34
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueThe AnalystSame topicAnalytical Chemistry and SensorsFrench-language works237,207