MétaCan
Menu
Back to cohort
Record W2216683958 · doi:10.1016/j.bios.2015.11.047

Highly sensitive detection of urinary protein variations using tilted fiber grating sensors with plasmonic nanocoatings

2015· article· en· W2216683958 on OpenAlexafffund
Tuan Guo, Fu Liu, Xing Liang, Xuhui Qiu, Yunyun Huang, Chen Xie, Peng Xu, Wei Mao, Bai‐Ou Guan, Jacques Albert

Bibliographic record

VenueBiosensors and Bioelectronics · 2015
Typearticle
Languageen
FieldEngineering
TopicAdvanced Fiber Optic Sensors
Canadian institutionsCarleton University
FundersFundamental Research Funds for the Central UniversitiesNatural Sciences and Engineering Research Council of CanadaNational Natural Science Foundation of ChinaCanada Research Chairs
KeywordsMaterials scienceRefractive indexBiosensorSurface plasmon resonanceDetection limitFiber Bragg gratingGratingPlasmonOptical fiberFiberOptoelectronicsMicrofluidicsOpticsNanotechnologyWavelengthNanoparticleChemistry

Abstract

fetched live from OpenAlex

Surface plasmon resonance (SPR) optical fiber biosensors can be used as a cost-effective and relatively simple-to-implement alternative to well established bulky prism configurations for high sensitivity biological sample measurements. The miniaturized size and remote operation ability offer them a multitude of opportunities for single-point sensing in hard-to-reach spaces, even possibly in vivo. The biosensor configuration reported in this work uses a tilted fiber Bragg grating (TFBG) in a commercial single mode fiber coated with a nanometer scale silver film. The key point is that by reducing the silver film thickness to around 20-30 nm (rather than 50 nm for optimal SPR excitation), different modes of the TFBG spectrum present very high but opposite sensitivities to refractive index (RI) changes around the TFBG. Experimental results obtained with the coated TFBG embedded inside a microfluidic channel show an amplitude sensitivity greater than 8000 dB/RIU (Refractive Index Unit) and a limit of detection of 10(-5)RIU. Using this device, the effect of different concentrations of protein in rat urine was clearly differentiated between healthy samples, nephropatic samples and samples from individuals under treatment, with a protein concentration sensitivity of 5.5 dB/(mg/ml) and a limit of detection of 1.5 × 10(-3)mg/ml. Those results show a clear relationship between protein outflow and variations in the RI of the urine samples between 1.3400 and 1.3408, pointing the way to the evaluation and development of new drugs for nephropathy treatments. The integration of TFBGs with microfluidic channels enables precise measurement control over samples with sub-microliter volumes and does not require accurate temperature control because of the elimination of the temperature cross-sensitivity inherent in TFBG devices. Integration of the TFBG with a hypodermic needle on the other hand would allow similar measurements in vivo. The proposed optical fiber/microfluidic plasmonic biosensor represents an appealing solution for rapid, low consumption and highly sensitive detection of analytes at low concentrations in medicine as well as in chemical and environmental monitoring.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.210
Teacher spread0.197 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations183
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueBiosensors and BioelectronicsSame topicAdvanced Fiber Optic SensorsFrench-language works237,207