MétaCan
Menu
Back to cohort
Record W2220231800 · doi:10.1117/12.2199232

CMOS buried multi-junction (BMJ) detector for bio-chemical analysis

2015· article· en· W2220231800 on OpenAlexaff
Guo‐Neng Lu, Thierry Courcier, Bastien Mamdy, Sylvain Feruglio, Paul G. Charette, Vincent Aimez, Olivier Romain, Patrick Pittet

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2015
Typearticle
Languageen
FieldEngineering
TopicCCD and CMOS Imaging Sensors
Canadian institutionsInstitut interdisciplinaire d'innovation technologiqueUniversité de Sherbrooke
Fundersnot available
KeywordsDetectorAmplifierNoise (video)CMOSChipPassivationDark currentOptoelectronicsSIGNAL (programming language)PhysicsCharge amplifierPhotodetectorElectronic engineeringElectrical engineeringMaterials scienceOpticsComputer scienceEngineeringLayer (electronics)NanotechnologyOperational amplifier

Abstract

fetched live from OpenAlex

The CMOS buried multi-junction (BMJ) detector with multiple outputs has distinct spectral responses that may be exploited for applications such as bio-chemical analysis. We tackle here dark current issue by identifying different components inside the detector structure. The identification methods are based on the observation of bias and temperature dependence, as well as measurements of test detector chip integrating different design variations. Surface thermal generation may become predominant when the detector size shrinks, thus causing dark current degradation. To prevent this effect, we propose a low-sized detector structure with passivation of all its surrounding Si/SiO2 interface areas. Also for the detector readout, we present a multi-channel charge-amplifier architecture with noise analysis. Effects of noise coming from amplifiers and related to the coupled detector’s dynamic conductances are illuminated. To pick up weak signals, synchronous detection can be implemented. A BDJ (Buried Double Junction) detector chip designed with a switched-phase architectural approach gives a minimum detectable signal of 15μlx@555nm or 1μlx@555nm at 27°C or – 10°C, for an integration time of 3s or 45s respectively.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.240
Teacher spread0.223 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIESame topicCCD and CMOS Imaging SensorsFrench-language works237,207