Record W2272851151 · doi:10.1088/0031-9155/60/21/8229

A fast and simple dose-calibrator-based quality control test for the radionuclidic purity of cyclotron-produced<sup>99m</sup>Tc

2015· article· en· W2272851151 on OpenAlexafffund
Jesse Tanguay, Xinchi Hou, Pedro L. Esquinas, Milan Vuckovic, K. Buckley, Paul Schaffer, François Bénard, T.J. Ruth, A. Ćeller

Bibliographic record

VenuePhysics in Medicine and Biology · 2015
Typearticle
Languageen
FieldMedicine
TopicRadiopharmaceutical Chemistry and Applications
Canadian institutionsTRIUMFBC Cancer AgencyUniversity of British Columbia
FundersBC Cancer AgencyNatural Resources Canada
KeywordsCyclotronImpurityRadiochemistryMaterials scienceGamma spectroscopySpectroscopyNuclear medicineAnalytical Chemistry (journal)ChemistryNuclear physicsDetectorPhysicsMedicineOptics

Abstract

fetched live from OpenAlex

Cyclotron production of 99mTc through the (100)Mo(p,2n)99mTc reaction channel is actively being investigated as an alternative to reactor-based (99)Mo generation by nuclear fission of (235)U. Like most radioisotope production methods, cyclotron production of 99mTc will result in creation of unwanted impurities, including Tc and non-Tc isotopes. It is important to measure the amounts of these impurities for release of cyclotron-produced 99mTc (CPTc) for clinical use. Detection of radioactive impurities will rely on measurements of their gamma (γ) emissions. Gamma spectroscopy is not suitable for this purpose because the overwhelming presence of 99mTc and the count-rate limitations of γ spectroscopy systems preclude fast and accurate measurement of small amounts of impurities. In this article we describe a simple and fast method for measuring γ emission rates from radioactive impurities in CPTc. The proposed method is similar to that used to identify (99)Mo breakthrough in generator-produced 99mTc: one dose calibrator (DC) reading of a CPTc source placed in a lead shield is followed by a second reading of the same source in air. Our experimental and theoretical analysis show that the ratio of DC readings in lead to those in air are linearly related to γ emission rates from impurities per MBq of 99mTc over a large range of clinically-relevant production conditions. We show that estimates of the γ emission rates from Tc impurities per MBq of 99mTc can be used to estimate increases in radiation dose (relative to pure 99mTc) to patients injected with CPTc-based radiopharmaceuticals. This enables establishing dosimetry-based clinical-release criteria that can be tested using commercially-available dose calibrators. We show that our approach is highly sensitive to the presence of 93gTc, 93mTc, 94gTc, 94mTc, 95mTc, 95gTc, and 96gTc, in addition to a number of non-Tc impurities.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.008
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.004
Threshold uncertainty score0.021

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.008
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.335
GPT teacher head0.463
Teacher spread0.128 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2015
Admission routes2
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicRadiopharmaceutical Chemistry and ApplicationsFrench-language works237,207