MétaCan
Menu
Back to cohort
Record W2273790971 · doi:10.1002/dta.1956

Liposomes as potential masking agents in sport doping. Part 2: Detection of liposome‐entrapped haemoglobin by flow cytofluorimetry

2016· article· en· W2273790971 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

fundA Canadian funder is recorded on the work.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueDrug Testing and Analysis · 2016
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicHemoglobin structure and function
Canadian institutionsnot available
FundersWorld Anti-Doping Agency
KeywordsLiposomeEthylene glycolChemistryChromatographyPEG ratioStreptavidinConjugated systemBiochemistryBiotinOrganic chemistry

Abstract

fetched live from OpenAlex

This work presents an analytical procedure for the identification and characterization of liposome-entrapped haemoglobins, based on flow cytofluorimetry. Flow cytofluorimetric detection is carried out following labelling by two distinct fluorescent reagents, an anti-haemoglobin antibody, fluorescein isothiocyanate conjugated, and an anti-poly(ethylene glycol) antibody, streptavidin-phycoerythrin conjugated. This experimental strategy allows the detection of liposome-entrapped haemoglobins in aqueous media, including plasma; the efficacy of the proposed approach has been verified on whole blood samples added with the liposomal formulation (ex-vivo). Additionally, the proposed technique allows the characterization of several key parameters in the study of liposomal haemoglobins, including, for instance (1) the determination of the degree of haemoglobin entrapment by liposomes; (2) the poly(ethylene glycol) insertion efficiency; and (3) the evaluation of liposome-entrapped haemoglobins stability following storage at 4 °C, allowing to follow both the process of haemoglobin loss from liposomes and the liposome degradation. The procedure is proposed for the detection and characterization of liposome-entrapped haemoglobin formulations to control their misuse in sport, but is also suggested for further applications in biological and clinical laboratory investigations. Copyright © 2016 John Wiley & Sons, Ltd.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.195
Threshold uncertainty score0.494

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.228
Teacher spread0.221 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it