MétaCan
Menu
Back to cohort
Record W2283204357

VALIDATION OF THE LESSER TROCHANTER PROFILE FOR PREDICTION OF FEMORAL ROTATION

2012· article· en· W2283204357 on OpenAlexaboutno aff
Ted Tufescu, Victoria Chau

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldMedicine
TopicHip and Femur Fractures
Canadian institutionsnot available
Fundersnot available
KeywordsRotation (mathematics)FemurIntramedullary rodGreater trochanterCadaveric spasmMedicineOrthodonticsOsteotomyMathematicsRadiographyExternal rotationSurgeryGeometry
DOInot available

Abstract

fetched live from OpenAlex

Purpose Incidence of malrotation of femoral fractures after intramedullary nailing is as high as 28%. Prevention of malrotation is superior to late derotation osteotomy. The lesser trochanter (LT) profile has been in use for some time as a radiographic landmark of femoral rotation. One of the authors has previously described a linear regression model that describes the relationship of the LT to rotation. This paper aims to validate the use of this equation in predicting femoral rotation. Method A survey was created and circulated online. Twenty images of cadaveric femurs of known rotation were chosen randomly from a large series. Thirty individuals with varying degrees of orthopaedic experience were invited to participate. Participants were asked to take measurements of the LT in a standardized fashion. Inter-observer variation for predicted rotation and the precision of predicted rotation was calculated. Results were grouped into those with the LT readily visible and those with the LT hidden by the femoral shaft. Results A pilot study found the standard deviation for films with the LT hidden was 10.8 degrees, and only 6.0 degrees for films with the LT visible. The mean difference between the predicted and actual rotation was equally high in both groups (18.3 and 17.3 degrees respectively). Conclusion Preliminary results found that the LT must be clearly visible to predict femoral rotation. This suggests that the surgeon should place the femur in a neutral or externally rotated position. In a favourable position most predictions were within a 6.0 degree spread, which would be sufficient to prevent a fifteen degree malrotation. Predicted rotation was however not precise enough to prevent a fifteen degree malrotation, regardless of LT visibility. The precision of predicted rotation may be improved by using a non-linear model. Such a model has recently been designed by a group of engineers at the University of Manitoba. The r squared value of the non-linear model was 0.88, in comparison to 0.78 for the linear equation. Precision may be further improved by using the contra-lateral LT for comparison.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.022
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.031

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.022
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.292
Teacher spread0.261 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2012
Admission routes1
Has abstractyes

Explore more

Same topicHip and Femur FracturesFrench-language works237,207