MétaCan
Menu
Back to cohort
Record W2288631236 · doi:10.1111/cid.12392

Stability and Marginal Bone Level Changes of SLActive Titanium‐Zirconium Implants Placed with Flapless Surgery: A Prospective Pilot Study

2016· article· en· W2288631236 on OpenAlexvenueno aff
Pınar Altinci, Gülşen Can, Onur Güneş, Caner Öztürk, Hakan Eren

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2016
Typearticle
Languageen
FieldMedicine
TopicReconstructive Surgery and Microvascular Techniques
Canadian institutionsnot available
FundersITI FoundationAnkara Universitesi
KeywordsDentistryTitaniumMedicineZirconiumProspective cohort studyMaterials scienceSurgeryMetallurgy

Abstract

fetched live from OpenAlex

BACKGROUND: Immediately-loaded, narrow-diameter implants can be a less invasive alternative for the implant-supported fixed rehabilitation of narrow, posterior crests. PURPOSE: To determine the stability and marginal bone level (MBL) changes of narrow-diameter, titanium-zirconium (TiZr) implants placed with flapless surgery and loaded immediately in the posterior region. MATERIALS AND METHODS: Thirty-eight TiZr implants (3.3 mm diameter, 10 mm length, Roxolid, Straumann AG) were placed in the posterior crests of 14 patients with computer-guided flapless surgery as a support of 3-unit posterior bridges. Eighteen implants were loaded immediately, and 20 implants were loaded conventionally. The implant stability quotients were determined at the 1, 2, 4, and 8. weeks of healing before conventional loading, and at the 3, 6, and 12. months after loading by resonance frequency analysis. The MBL changes were measured by digital radiography. RESULTS: The surgical protocols were accomplished without any biological complications. There was no significant difference in the stability changes of TiZr implants between the loading groups (p > .05). The MBL changes were -0.18 ± 0.27 mm and -0.24 ± 0.27 mm at the 12. month of immediate and conventional loading, respectively, which was not statistically significant (p > .05). CONCLUSION: The stability and MBL changes of TiZr implants supporting posterior 3-unit bridges were clinically acceptable at the first year of loading.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.035
Threshold uncertainty score0.628

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0050.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.002
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.218
GPT teacher head0.423
Teacher spread0.206 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations15
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related ResearchSame topicReconstructive Surgery and Microvascular TechniquesFrench-language works237,207