MétaCan
Menu
← Back to cohort

Evaluation of clinical markup with CT simulation in whole brain radiation therapy

2007· article· en· W2296977397 on OpenAlexaff
Y. Wang, N. Makhani, May Tsao

Bibliographic record

VenueJournal of Clinical Oncology · 2007
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsSunnybrook Health Science Centre
Fundersnot available
KeywordsMedicineNuclear medicineRadiation therapyRadiology

Abstract

fetched live from OpenAlex

2043 Background: Two types of clinical markup have been used for whole brain radiation therapy (WBRT), but the extent of dose coverage and sparing of the lens is unknown. This study is designed to evaluate clinical markup with CT simulation. Methods: CT simulation images of the brain from 20 random adult patients were included in this study. Two types of inferior field borders were generated to mimic the 2 types of clinical markup of WBRT: from superior orbital ridge (SOR) to tragus, and from SOR to inferior tragal notch (ITN). A field margin of 1 cm from contoured brain (along base of skull) was used in CT simulation, except near the orbital globe where 0.5 cm margin to eye shielding was used. Two opposed lateral fields with 6 MV photon were used to generate 3 WBRT plans in each patient: clinical markup with SOR to tragus, SOR to ITN, and CT simulation. Dose volume histograms of the brain and lens were generated. The primary end point was dose coverage of whole brain with clinical markup. The secondary end point was sparing of the lens. Results: Patients with clinical markup using SOR to tragus or SOR to ITN had significantly larger median brain volume receiving less than 95% of the prescribed dose, 37.0 mL and 7.8 mL (respectively) compared to CT simulation 0 mL (P < 0.001). All patients with SOR to tragus and most patients (95%) with SOR to ITN clinical markup had underdosing in the regions of inferior frontal lobe, temporal lobe and posterior fossa. There was no significant difference in the dose to the lens between CT simulation and clinical markup using SOR to tragus (P = 0.18) or SOR to ITN (P = 0.90). Conclusions: Whole brain radiation therapy with clinical markup using either SOR to tragus or SOR to ITN results in underdosing at the inferior frontal lobe, temporal lobe and posterior fossa. Sparing of the lens is adequately achieved with clinical markup. No significant financial relationships to disclose.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.013
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.016

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.013
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.147
GPT teacher head0.559
Teacher spread0.412 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Clinical Oncology→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→