MétaCan
Menu
Back to cohort
Record W2298815274 · doi:10.1039/c6an00251j

A highly sensitive and simply operated protease sensor toward point-of-care testing

2016· article· en· W2298815274 on OpenAlexaff
Seonhwa Park, Yu Mi Shin, Jeongwook Seo, Ji‐Joon Song, Haesik Yang

Bibliographic record

VenueThe Analyst · 2016
Typearticle
Languageen
FieldEngineering
TopicAdvanced Sensor and Energy Harvesting Materials
Canadian institutionsKootenay Association for Science & Technology
FundersNational Research Foundation of KoreaMinistry of Science, ICT and Future Planning
KeywordsDetection limitChemistryChromatographyDithiothreitolProteaseAdsorptionReagentElectrochemical gas sensorElectrochemistryElectrodeBiochemistryEnzymeOrganic chemistry

Abstract

fetched live from OpenAlex

Protease sensors for point-of-care testing (POCT) require simple operation, a detection period of less than 20 minutes, and a detection limit of less than 1 ng mL(-1). However, it is difficult to meet these requirements with protease sensors that are based on proteolytic cleavage. This paper reports a highly reproducible protease sensor that allows the sensitive and simple electrochemical detection of the botulinum neurotoxin type E light chain (BoNT/E-LC), which is obtained using (i) low nonspecific adsorption, (ii) high signal-to-background ratio, and (iii) one-step solution treatment. The BoNT/E-LC detection is based on two-step proteolytic cleavage using BoNT/E-LC (endopeptidase) and l-leucine-aminopeptidase (LAP, exopeptidase). Indium-tin oxide (ITO) electrodes are modified partially with reduced graphene oxide (rGO) to increase their electrocatalytic activities. Avidin is then adsorbed on the electrodes to minimize the nonspecific adsorption of proteases. Low nonspecific adsorption allows a highly reproducible sensor response. Electrochemical-chemical (EC) redox cycling involving p-aminophenol (AP) and dithiothreitol (DTT) is performed to obtain a high signal-to-background ratio. After adding a C-terminally AP-labeled oligopeptide, DTT, and LAP simultaneously to a sample solution, no further treatment of the solution is necessary during detection. The detection limits of BoNT/E-LC in phosphate-buffered saline are 0.1 ng mL(-1) for an incubation period of 15 min and 5 fg mL(-1) for an incubation period of 4 h. The detection limit in commercial bottled water is 1 ng mL(-1) for an incubation period of 15 min. The developed sensor is selective to BoNT/E-LC among the four types of BoNTs tested. These results indicate that the protease sensor meets the requirements for POCT.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.003
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0020.001
Research integrity0.0030.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.226
Teacher spread0.208 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations20
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueThe AnalystSame topicAdvanced Sensor and Energy Harvesting MaterialsFrench-language works237,207