MétaCan
Menu
Back to cohort
Record W2302131767 · doi:10.14288/1.0072464

Multi-energy systems simulator for hourly management and optimization of GHG emissions and fuel costs

2011· article· en· W2302131767 on OpenAlexaboutno aff
César A. López

Bibliographic record

VenuecIRcle (University of British Columbia) · 2011
Typearticle
Languageen
FieldEngineering
TopicIntegrated Energy Systems Optimization
Canadian institutionsnot available
Fundersnot available
KeywordsGreenhouse gasEnvironmental economicsEnergy (signal processing)Environmental scienceComputer scienceSimulationAutomotive engineeringEngineeringEconomics

Abstract

fetched live from OpenAlex

Many legacy infrastructures are reaching the end of their service life. The necessary replacement of these infrastructures creates an opportunity to replace them with environmentally friendly and innovative systems. The steam plant at the University of British Columbia is one of those cases requiring replacement due to aging. The steam generation boilers are, on average, 53 years old and have short expected remaining service. The boilers process is fed by natural gas as main fuel. It was identified that almost 80% of the CO₂e emissions on campus are produced from the use of gas for heating purposes. UBC is worldwide recognized for being one of the most sustainable university campuses, and the first university in Canada awarded a gold rating in sustainability. UBC’s GHG emissions targets for Kyoto protocol were reached in 2007; at that point, new aggressive reduction targets were established, aiming for 33% by 2015, 67% by 2020 and 100% by 2050. These reductions are expressed in tonnes of CO₂e. The situation described offers an opportunity to explore alternatives for the Steam Plant potential replacements. The Infrastructures Interdependencies Simulator (I2Sim) was selected as simulation platform for this study. The simulator allows real-time resource management using hourly historical operational data. To meet the campus thermal requirements, the system considers biomass cogeneration, heat pump, and excess electricity to offset traditional natural gas fuel sources. All technologies take advantage of real-time management of fuels allocation to reduce GHG emissions. A parallel distribution system based on hot-water is modeled, because of the potential in increasing the overall heating system performance. Four modeling scenarios are constructed, showing that fuel costs can be reduced by 51%, GHG emissions reduced by 76% and overall energy consumption reduced by 29%. The simulator is a first step in integrating all critical infrastructures into a Smart Energy MicroGrid paradigm.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.719
Threshold uncertainty score0.980

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.156
Teacher spread0.147 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2011
Admission routes1
Has abstractyes

Explore more

Same venuecIRcle (University of British Columbia)Same topicIntegrated Energy Systems OptimizationFrench-language works237,207