MétaCan
Menu
Back to cohort
Record W2314203553 · doi:10.2118/110518-ms

Comparison Study of Capillary Pressure Curves Obtained Using Traditional Centrifuge and Magnetic Resonance Imaging Techniques

2008· article· en· W2314203553 on OpenAlexafffundabout
Derrick Green, John Gardner, B. J. Balcom, Michael McAloon, P. F. de J. Cano-Barrita

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldPhysics and Astronomy
TopicNMR spectroscopy and applications
Canadian institutionsUniversity of New Brunswick
FundersNatural Sciences and Engineering Research Council of CanadaAtlantic Canada Opportunities Agency
KeywordsCapillary pressureCapillary actionSaturation (graph theory)CentrifugeMechanicsMagnetic resonance imagingMaterials sciencePorous mediumChemistryPorosityPhysicsComposite materialMathematics

Abstract

fetched live from OpenAlex

Abstract The current study is a comparison trial of a new Magnetic Resonance Imaging (MRI) method for acquiring capillary pressure versus traditional techniques. This study is meant to evaluate the methodology and workflow by performing measurements at the University of New Brunswick, Canada and on-site with CoreLab in Houston, TX, USA. This study focuses on gas-brine primary drainage capillary pressure systems. Traditional centrifuge capillary pressure measurements require the fluid(s) to reach equilibrium at many different speeds. This is very time consuming as each equilibrium step can take a couple of days. In addition, the inlet saturation must be computed using an approximate solution that is known to cause errors. Porous plate capillary pressure measurements are considered the most accurate but acquiring the complete curve can take months. The new method (GIT-CAP) centrifuges the core plugs then directly measures the water saturation distribution inside the core plug using MRI. The measured water saturation together with the known centrifugal force directly leads to a capillary pressure curve. Conventional medical based MRI methods have difficulty in relating the detected signal intensity to water or oil saturation. This is because the MRI image intensity depends on the environment of hydrogen atoms which changes based on saturation level. In this work, we use a new MRI method, one dimensional centric scan Single-point Ramped Imaging with T1 Enhancement (SPRITE), in which the detected signal is directly proportional to the amount of water or oil present. The new technique measures the capillary pressure curve more quickly and accurately. It is also three to five times faster since only two to three centrifuge speeds are required (versus seven to ten). In some rock types, this reduces the measurement duration from many weeks to days. The new technique is also potentially more accurate as it directly measures the water saturation in the rock instead of relying on a calculation using a measurement of the expelled water. The current study focuses on gas-water systems comparing traditional capillary pressure measurements with the new MRI-based method.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.010
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.016

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.010
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0020.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.029
GPT teacher head0.331
Teacher spread0.302 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations38
Published2008
Admission routes3
Has abstractyes

Explore more

Same topicNMR spectroscopy and applicationsFrench-language works237,207