A biomechanical comparison of static versus dynamic lag screw modes for cephalomedullary nails used to fix unstable peritrochanteric fractures

2011· article· en· W2314732179 on OpenAlexaff
Paul R.T. Kuzyk, Suraj Shah, Rad Zdero, Michael Olsen, James P. Waddell, Emil H. Schemitsch

Bibliographic record

VenueThe Journal of Trauma: Injury, Infection, and Critical Care · 2011
Typearticle
Languageen
FieldMedicine
TopicHip and Femur Fractures
Canadian institutionsToronto Metropolitan UniversityUniversity of TorontoSt. Michael's HospitalMount Sinai Hospital
FundersStryker
KeywordsFemurStiffnessNail (fastener)Lag screwOrthodonticsBiomechanicsMaterials scienceAnatomyComposite materialSurgeryMedicine

Abstract

fetched live from OpenAlex

BACKGROUND: The gamma nail has an option to statically lock its lag screw (static mode) or to allow its lag screw to move within the nail to compress the intertrochanteric fracture (dynamic mode). The purpose of this study was to compare the biomechanical stiffness of static and dynamic lag screw modes for a cephalomedullary nail used to fix an unstable peritrochanteric fracture. METHODS: Unstable four-part peritrochanteric fractures were created in 30 synthetic femurs and fixed with Long Gamma 3 Nails. Mechanical tests were conducted for axial, lateral, and torsional stiffness with intact femurs, femur-nail constructs with static lag screw mode,and femur-nail constructs with dynamic lag screw mode. A paired Student's t test was used for all statistical comparisons between test groups. RESULTS: Axial and torsional stiffness of intact femurs was significantly greater than femur-nail constructs (p < 0.01 all comparisons),whereas lateral stiffness was significantly less (p < 0.01 all comparisons). Axial stiffness of the femur-nail construct was significantly greater (p < 0.01) in static mode (484.3 N/mm 80.2 N/mm) than in dynamic mode (424.1 N/mm 78.0 N/mm).Lateral stiffness was significantly greater (p < 0.01) in static mode (113.9 N/mm 8.4 N/mm) than in dynamic mode (109.5N/mm 8.8 N/mm). Torsional stiffness was significantly greater (p = 0.02) in dynamic mode (114.5 N/mm 28.2 N/mm) than in static mode (111.7 N/mm 27.0 N/mm). DISCUSSION: There is a 60 N/mm (12.4%) reduction in axial stiffness when the lag screw is in dynamic mode. Given the statistically significant reduction in axial and lateral stiffness with use of the dynamic mode, static lag screw mode should be further explored clinically for treatment of unstable peritrochanteric fractures.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.165
Threshold uncertainty score0.489

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.063
GPT teacher head0.398
Teacher spread0.335 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations29
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueThe Journal of Trauma: Injury, Infection, and Critical CareSame topicHip and Femur FracturesFrench-language works237,207