MétaCan
Menu
Back to cohort
Record W2317455302 · doi:10.1111/pace.12868

Arrhythmic Risk Following Recovery of Left Ventricular Ejection Fraction in Patients with Primary Prevention ICD

2016· article· en· W2317455302 on OpenAlexaff
Maxime Berthelot‐Richer, Francis Bonenfant, Marie‐Annick Clavel, Paul Farand, François Philippon, Félix Ayala-Paredes, Btissama Essadiqi, Mariano Badra‐Verdu, Jean-François Roux

Bibliographic record

VenuePacing and Clinical Electrophysiology · 2016
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsInstitut universitaire de cardiologie et de pneumologie de QuébecCentre Hospitalier Universitaire de SherbrookeUniversité Laval
Fundersnot available
KeywordsMedicineEjection fractionCardiologyInternal medicinePrimary preventionImplantable cardioverter-defibrillatorSecondary preventionHeart failure

Abstract

fetched live from OpenAlex

BACKGROUND: Left ventricular ejection fraction (LVEF) recovers during follow-up in a significant proportion of patients implanted with a cardioverter defibrillator (ICD) for primary prevention. Little is known about the midterm arrhythmic risk in this population, particularly in relation to the presence or absence of ischemic cardiomyopathy. METHODS AND RESULTS: We retrospectively analyzed 286 patients with an ICD implanted for primary prevention between 2002 and 2010. Patients were divided into two groups based on their last LVEF assessment: (1) Recovery, defined as an LVEF > 35%; and (2) No-Recovery, defined as an LVEF ≤ 35%. Kaplan-Meir curves and multivariate Cox regression analysis were performed separately for patients with ischemic (211 patients) and nonischemic (75 patients) cardiomyopathy. Forty-nine patients (17.1%) had LVEF recovery to >35% at last follow-up. Overall, 72 patients (25.2%) experienced ventricular arrhythmias requiring ICD therapy during a median follow-up of 4.4 years. With multivariate Cox regression, LVEF recovery was associated with a lower arrhythmic risk in the whole cohort (hazard ratio [HR]: 0.38 [0.13-0.85]; P = 0.02) and in the nonischemic cardiomyopathy cohort (HR: 0.10 [0.005-0.55]; P = 0.005), but not in the ischemic cardiomyopathy cohort (HR: 0.84 [0.25-2.10]; P = 0.74). CONCLUSION: In conclusion, patients with nonischemic cardiomyopathy who improved their LVEF to >35% after primary prevention ICD implantation were at very low absolute arrhythmic risk. Our study raises the possibility that the LVEF cutoff to safely withhold ICD replacement might be higher in patients with ischemic compared to nonischemic cardiomyopathy. This will need to be confirmed in prospective studies.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.280
Teacher spread0.272 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2016
Admission routes1
Has abstractyes

Explore more

Same venuePacing and Clinical ElectrophysiologySame topicCardiac pacing and defibrillation studiesFrench-language works237,207