MétaCan
Menu
Back to cohort
Record W2320210677 · doi:10.1017/s0317167100010532

Reproducibility of Semi-Automated Measurement of Carotid Stenosis on CTA

2010· article· en· W2320210677 on OpenAlexaffvenue
Jeremy H. White, Eric Bartlett, Aditya Bharatha, Richard I. Aviv, Allan J. Fox, Andrew Thompson, Richard Bitar, Sean Symons

Bibliographic record

VenueCanadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · 2010
Typearticle
Languageen
FieldMedicine
TopicCerebrovascular and Carotid Artery Diseases
Canadian institutionsUniversity of Toronto
Fundersnot available
KeywordsReproducibilityStenosisMedicineCarotid arteriesRadiologyNuclear medicineInternal medicineChemistryChromatography

Abstract

fetched live from OpenAlex

PURPOSE: To compare the reproducibility of semi-automated vessel analysis software to manual measurement of carotid artery stenosis on computed tomography angiography (CTA). METHODS: Two observers separately analyzed 81 carotid artery CTAs using semi-automated vessel analysis software according to a blinded protocol. The software measured the narrowest stenosis in millimeters (mm), distal internal carotid artery (ICA) in mm, and calculated percent stenosis based on NASCET criteria. One observer performed this task twice on each carotid, the second analysis delayed two months in order to mitigate recall bias. Two other observers manually measured the narrowest stenosis in mm, distal ICA in mm, and calculated NASCET percent stenosis in a blinded fashion. Correlation coefficients were calculated for each group comparing the narrowest stenosis in mm, distal ICA in mm, and NASCET percent stenosis. RESULTS: The semi-automated vessel analysis software provided excellent intraobserver correlation for narrowest stenosis in mm, distal ICA in mm, and NACSET percent stenosis (Pearson correlation coefficients of 0.985, 0.954, and 0.977 respectively). The semi-automated vessel analysis software provided excellent interobserver correlation (0.925, 0.881, and 0.892 respectively). The interobserver correlation for manual measurement was good (0.595, 0.625, and 0.555 respectively). There was a statistically significant difference in the interobserver correlation between the semi-automated vessel analysis software observers and the manual measurement observers (P < 0.001). CONCLUSION: Semi-automated vessel analysis software is a highly reproducible method of quantifying carotid artery stenosis on CTA. In this study, semi-automated vessel analysis software determination of carotid stenosis was shown to be more reproducible than manual measurement.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.016
metaresearch head score (Gemma)0.059
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: Reproducibility · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.984
Threshold uncertainty score0.085

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0160.059
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.038
GPT teacher head0.273
Teacher spread0.234 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

Study designObservational
DomainReproducibility
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations18
Published2010
Admission routes2
Has abstractyes

Explore more

Same venueCanadian Journal of Neurological Sciences / Journal Canadien des Sciences NeurologiquesSame topicCerebrovascular and Carotid Artery DiseasesFrench-language works237,207