MétaCan
Menu
Back to cohort
Record W2324811592 · doi:10.1021/ac501081b

Reducing pH Gradients in Free-Flow Electrophoresis

2014· article· en· W2324811592 on OpenAlexafffund
Fletcher J. Agostino, Leonid T. Cherney, Mirzo Kanoatov, Sergey N. Krylov

Bibliographic record

VenueAnalytical Chemistry · 2014
Typearticle
Languageen
FieldEngineering
TopicInnovative Microfluidic and Catalytic Techniques Innovation
Canadian institutionsYork University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsChemistryVolumetric flow rateElectrolysisVolume (thermodynamics)Flow (mathematics)Analytical Chemistry (journal)ElectrophoresisFlow chemistryElectrodeChromatographyMechanicsElectrolyteThermodynamicsCatalysis

Abstract

fetched live from OpenAlex

Small-volume continuous-flow synthesis (small-volume CFS) offers a number of benefits for use in small-scale chemical production and exploratory chemistry. Typically, small-volume CFS is followed by discontinuous purification; however, a fully continuous synthesis-purification combination is more attractive. Milli free-flow electrophoresis (mFFE) is a promising continuous-flow purification technique that is well suited for integration with small-volume CFS. The purification stability of mFFE, however, needs to be significantly improved before it can be feasible for this combination. One of the major sources of instability of mFFE is attributed to the ions produced as a result of electrolysis. These ions can form pH and conductivity gradients in mFFE, which are detrimental to separation quality. The severity of these gradients has not been thoroughly studied in mFFE. In this paper, we have experimentally demonstrated that detrimental pH gradients occur at flow rates of 8 mL/min and less, and electric field strengths of 25 V/cm and greater. To decrease the pH gradients, it is necessary to evacuate H(+) and OH(-) as soon as they are generated; this can be done by increasing local hydrodynamic flow rates. We calculated the necessary flow rate, to be applied at the electrode, which can effectively wash away both ions before they can cause a detrimental pH gradient. These optimized flow rates can be attained by designing a device that incorporates deep channels. We have confirmed the effectiveness of these channels using a prototyped device. The new design allows mFFE users to work over a wider range of flow-rate and electric-field conditions without experiencing significant changes in pH.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.214
Teacher spread0.208 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2014
Admission routes2
Has abstractyes

Explore more

Same venueAnalytical ChemistrySame topicInnovative Microfluidic and Catalytic Techniques InnovationFrench-language works237,207