MétaCan
Menu
Back to cohort
Record W2326497434 · doi:10.1093/ndt/gfw044

Clinical safety and performance of VIVIA: a novel home hemodialysis system

2016· article· en· W2326497434 on OpenAlexaff
Angelito A. Bernardo, Thomas Marbury, Phil McFarlane, Robert P. Pauly, Michael Amdahl, Jason Demers, Audrey M. Hutchcraft, John K. Leypoldt, Mark Minkus, Matt Muller, R. Stallard, Bruce F. Culleton

Bibliographic record

VenueNephrology Dialysis Transplantation · 2016
Typearticle
Languageen
FieldMedicine
TopicDialysis and Renal Disease Management
Canadian institutionsUniversity of Alberta HospitalAlberta Hospital EdmontonSt. Michael's Hospital
Fundersnot available
KeywordsMedicineHemodialysisSurgery

Abstract

fetched live from OpenAlex

Background: The VIVIA Hemodialysis System (Baxter Healthcare Corporation, Deerfield, IL, USA) was designed for patient use at home to reduce the burden of treatment and improve patient safety. It has unique features including extended use of the dialyzer and blood set through in situ hot-water disinfection between treatments; generation of on-line infusible-quality dialysate for automated priming, rinseback and hemodynamic support during hypotension and a fully integrated access disconnect sensor. Methods: The safety and performance of VIVIA were assessed in two clinical studies. A first-in-man study was a prospective, single-arm study that involved 22 prevalent hemodialysis (HD) patients who were treated for ∼4 h, four times a week, for 10 weeks. A second clinical study was a prospective, single-arm study (6-8 h of dialysis treatment at night three times a week) that involved 17 prevalent patients treated for 6 weeks. Results: There were 1114 treatments from the two studies (first-in-man study, 816; extended duration study, 298). Adverse events (AEs) were similar in the two studies to those expected for prevalent HD patients. No deaths and no device-related serious AEs occurred. Adequacy of dialysis ( Kt / V ) urea in both clinical trials was well above the clinical guidelines. VIVIA performed ultrafiltration accurately as prescribed in the two studies. The majority of patients achieved 10 or more uses of the dialyzer. Endotoxin levels and bacterial dialysate sampling met infusible-quality dialysate standards. Conclusion: These results confirm the safety and expected performance of VIVIA.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.023

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.256
Teacher spread0.244 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueNephrology Dialysis TransplantationSame topicDialysis and Renal Disease ManagementFrench-language works237,207