MétaCan
Menu
Back to cohort

GW24-e2927 Low dose quantitative myocardial CT perfusion with adaptive statistical iterative reconstruction: a microspheres validation study

2013· article· en· W2326981337 on OpenAlexaff
Aaron So, Jiang Hsieh, Jean‐Baptiste Thibault, Kelley R. Branch, Ting‐Yim Lee

Bibliographic record

VenueHeart · 2013
Typearticle
Languageen
FieldEngineering
TopicPhotoacoustic and Ultrasonic Imaging
Canadian institutionsRobarts Clinical TrialsLawson Health Research Institute
Fundersnot available
KeywordsMedicineNuclear medicinePerfusionScannerPerfusion scanningMyocardial perfusion imagingRadiology

Abstract

fetched live from OpenAlex

Objectives We validated the effectiveness of adaptive statistical iterative reconstruction (ASIR, GE Healthcare (GE)) for minimising image noise in low dose quantitative myocardial perfusion (MP) imaging against microspheres MP measurement. Methods Iodinated contrast (Isovue 370, 0.7 mgI × kg -1 ) was injected at 3 to 4 mls-1 into 68 ± 25 kg normal pigs via an ear vein and the heart was scanned using a GE Discovery 750HD scanner with a prospectively ECG triggered dynamic protocol (Snapshot Pulse (SSP), GE): axial scan every 1–2 heart beats for 22 scans using 140 kV, 0.35 s gantry period and 80 mA (normal dose). MP measurement was repeated with the x-ray tube current reduced to 20 mA (low dose). The normal- and low-dose SSP images were reconstructed using filtered backprojection (FBP) (SSP80) and both FBP (SSP20FBP) and ASIR (SSP20ASIR) respectively. All images were corrected for beam hardening from which MP maps were generated using CT Perfusion (GE). After the CT perfusion studies, fluorescent microspheres were injected into the left atrial appendage of the heart to measure MP. Mean MP measured with microspheres and the three CT image sets in 45 segments from the lateral, apical and septal wall in 15 slices from three pigs were compared using linear regression and Bland-Altman analysis. Effective dose (ED) of each SSP protocol was estimated from the dose-length product provided by the scanner. Results SSP80 images exhibited the highest correlation with microspheres (R = 0.69) compared to SSP20ASIR (R = 0.60) and SSP20FBP (R = 0.57). SSP80 images also showed the smallest difference in mean MP from microspheres and narrowest limits of agreement with microspheres (7.0 and -32.9 to 46.8 ml × min -1 × 100g -1 (80)) compared to SSP20ASIR (11.3 and -35.3 to 57.8 (93)) and SSP20FBP (15.7 and -32.8 to 64.1 (97)). ED of the SSP80 and SSP20 protocols were 4.5 and 1.1 mSv respectively. Conclusions Noise in low dose SSP images reconstructed with FBP was excessive which led to less accurate and reproducible MP estimation with CT Perfusion but such errors could be reduced with ASIR. With the proposed image acquisition and reconstruction approaches, MP measurement with low dose CT Perfusion is a feasible alternative to MRI and SPECT for studying ischemic heart disease.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.499
Threshold uncertainty score0.681

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.233
Teacher spread0.222 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueHeartSame topicPhotoacoustic and Ultrasonic ImagingFrench-language works237,207