MétaCan
Menu
Back to cohort
Record W2329714167 · doi:10.1021/ac303543r

Microplate-Based Colorimetric Detection of Free Hydrogen Sulfide

2013· article· en· W2329714167 on OpenAlexaff
Artur P. Jarosz, Terence Yep, Bülent Mutus

Bibliographic record

VenueAnalytical Chemistry · 2013
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicSulfur Compounds in Biology
Canadian institutionsUniversity of Windsor
Fundersnot available
KeywordsChemistryAbsorbanceDetection limitHydrogen sulfideCystathionine gamma-lyaseCysteineCystathionine beta synthaseColorimetryChromatographyEnzymeBiochemistrySulfurOrganic chemistry

Abstract

fetched live from OpenAlex

Hydrogen sulfide (H2S) has recently been recognized as an important physiologically relevant gasotransmitter. Produced by the enzymes involved in the transsulfuration pathway, cystathionine β-synthase (CBS) and cystathionine γ-lyase (CSE), H2S has been implicated to control biological activity in virtually every organ system. In recent years it is being recognized that many commonly used H2S assays do not measure free H2S specifically and may be prone to artifacts. This has led to large variations in the reported H2S biological concentrations. In order to accurately study H2S's functions in biological systems accurate assays which measure free H2S specifically are required. In this work we present a simple microplate-based colorimetric assay for H2S gas. The underside of a 96-well microplate cover was coated with Nafion polymer doped with Ag(+) ions. H2S is a highly volatile gas, and as it is volatilized in the microplate well it reacts with Ag(+) to produce Ag2S nanoparticles, which have a strong absorbance in the low-UV range. By monitoring the absorbance change from formation of Ag2S nanoparticles, H2S production can be monitored in real time. The assay has a limit of detection (LOD) of 2.61 nmol (8.70 μM) and a liner range up to 30 nmol (100 μM). Using the assay, the KM and Vmax of recombinant CSE enzyme were determined to be 11.13 ± 0.57 mM and 0.45 ± 0.01 nmol min(-1), respectively. H2S production from mouse liver homogenate under aerobic conditions in the presence of cysteine was measured and determined to be 4.89 ± 0.19 nmol min(-1) mL(-1) homogenate. The assay is simple, low cost, and specific to free H2S gas.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.635

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.228
Teacher spread0.219 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations88
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueAnalytical ChemistrySame topicSulfur Compounds in BiologyFrench-language works237,207