Microplate-Based Colorimetric Detection of Free Hydrogen Sulfide
Bibliographic record
Abstract
Hydrogen sulfide (H2S) has recently been recognized as an important physiologically relevant gasotransmitter. Produced by the enzymes involved in the transsulfuration pathway, cystathionine β-synthase (CBS) and cystathionine γ-lyase (CSE), H2S has been implicated to control biological activity in virtually every organ system. In recent years it is being recognized that many commonly used H2S assays do not measure free H2S specifically and may be prone to artifacts. This has led to large variations in the reported H2S biological concentrations. In order to accurately study H2S's functions in biological systems accurate assays which measure free H2S specifically are required. In this work we present a simple microplate-based colorimetric assay for H2S gas. The underside of a 96-well microplate cover was coated with Nafion polymer doped with Ag(+) ions. H2S is a highly volatile gas, and as it is volatilized in the microplate well it reacts with Ag(+) to produce Ag2S nanoparticles, which have a strong absorbance in the low-UV range. By monitoring the absorbance change from formation of Ag2S nanoparticles, H2S production can be monitored in real time. The assay has a limit of detection (LOD) of 2.61 nmol (8.70 μM) and a liner range up to 30 nmol (100 μM). Using the assay, the KM and Vmax of recombinant CSE enzyme were determined to be 11.13 ± 0.57 mM and 0.45 ± 0.01 nmol min(-1), respectively. H2S production from mouse liver homogenate under aerobic conditions in the presence of cysteine was measured and determined to be 4.89 ± 0.19 nmol min(-1) mL(-1) homogenate. The assay is simple, low cost, and specific to free H2S gas.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".