MétaCan
Menu
Back to cohort
Record W2331120639 · doi:10.1227/neu.0b013e3182045803

A Moveable 3-Tesla Intraoperative Magnetic Resonance Imaging System

2010· article· en· W2331120639 on OpenAlexafffund
Michael Lang, John J. Kelly, Garnette R. Sutherland

Bibliographic record

VenueOperative Neurosurgery · 2010
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsFoothills Medical CentreUniversity of Calgary
FundersUniversity of CalgaryAlberta Health Services
KeywordsInterventional magnetic resonance imagingMedicineMagnetic resonance imagingImage qualityNeuronavigationMagnetIntraoperative MRIRadiologyMedical physicsComputer sciencePhysicsArtificial intelligence

Abstract

fetched live from OpenAlex

BACKGROUND: Based on success with a prototype 1.5T intraoperative magnetic resonance imaging (iMRI) system and the desire for increased signal-to-noise ratio, along with its relationship to image quality and advanced applications, a 3.0T system that uses the same novel moveable magnet configuration was developed. OBJECTIVE: To assess clinical applicability by prospectively applying the higher-field system to a neurosurgical cohort. METHODS: Upgrading to 3.0T required substantial modification of an existing iMRI-equipped operating room. The 1.5T magnet was replaced with a ceiling-mounted, moveable 3.0T magnet with a 70-cm working aperture. Local radiofrequency shielding was replaced with whole-room shielding. A new hydraulic operating table, high-performance gradients, and advanced image processing software were also installed. The new system was used as an adjunct to standard neurosurgical practice. RESULTS: The iMRI system upgrade required 6 months. Since completion, the 3.0T iMRI system has successfully guided neurosurgery in 120 patients without system failure in a patient-focused environment. Intraoperative image quality was superior to that obtained at 1.5T and enabled intraoperative acquisition of advanced imaging sequences, including tractography. Intraoperative imaging was found to modify surgery in a substantial number of patients. CONCLUSION: Implementation of an iMRI system based on a moveable 3.0T magnet is feasible. From clinical experience with 120 patients, iMRI at 3.0T is safe, reliable, and capable of directing image-guided surgery with exceptional image quality.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.005
Threshold uncertainty score0.016

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0050.003

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.285
Teacher spread0.276 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations29
Published2010
Admission routes2
Has abstractyes

Explore more

Same venueOperative NeurosurgerySame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207