MétaCan
Menu
Back to cohort
Record W2332115675 · doi:10.1097/md.0000000000000282

Biomechanical Evaluation of Interfragmentary Compression At Tibia Plateau Fractures In Vitro Using Different Fixation Techniques

2015· article· en· W2332115675 on OpenAlexaff
Kodi Edson Kojima, Boyko Gueorguiev, G. Seva, Karl Stoffel, Rafael Garcia de Oliveira, Ursula Eberli, Tomás Nicolino, Mark Lenz

Bibliographic record

VenueMedicine · 2015
Typearticle
Languageen
FieldMedicine
TopicBone fractures and treatments
Canadian institutionsGeneral Dynamics (Canada)
FundersAO Foundation
KeywordsMedicineTibiaCancellous boneCompression (physics)OsteosynthesisCortical boneOsteoporosisFixation (population genetics)BiomechanicsOrthodonticsOsteotomyReduction (mathematics)DentistrySurgeryAnatomyMaterials scienceInternal medicineMathematicsComposite material

Abstract

fetched live from OpenAlex

Reliable osteosynthesis of intraarticular fractures depends on lasting interfragmentary compression. Its amount differs in the applied fixation method. The interfragmentary compression of cancellous and cortical lag screws and angle stable locking plates was quantified in an osteoporotic and non-osteoporotic synthetic human bone model.A split fracture of the lateral tibia plateau (AO/OTA type 41-B1.1) was mimicked by an osteotomy in right adult synthetic human tibiae with hard or soft cancellous bone. Specimens were fixed with either two 6.5 mm cancellous, four 3.5 mm cortical lag screws, or 3.5 mm LCP proximal lateral tibia plate preliminary compresed by a reduction clamp (n = 5 per group). A pressure sensor film was used to register the interfragmentary compression. One-way analysis of variance (ANOVA) with Bonferroni post hoc correction was performed for statistical analysis (p < 0.05).Interfragmentary compression under reduction clamp was 0.59 ± 0.12 MPa in the non-osteoporotic and 0.55 ± 0.14 MPa in the osteoporotic group. The locking plate itself maintained the compression in non-osteoporotic (0.53 ± 0.11 MPa) and osteoporotic bone (0.50 ± 0.14 MPa). Four 3.5 mm cortical lag screws provided a compression of 1.69 ± 0.65 MPa in non-osteoporotic bone, being not significantly different to the osteoporotic bone group (1.43 ± 0.47 MPa, P = 1.0). Two 6.5 mm cancellous lag screws showed a significantly higher compression in non-osteoporotic (2.1 ± 0.59 MPa) compared to osteoporotic (0.77 ± 0.21 MPa, P < 0.01) bone.Angle stable locking plates maintained the compression preliminarily applied by a reduction clamp. Two 6.5 mm cancellous lag screws are especially suited for non-osteoporotic bone, whereas four 3.5 mm cortical screws exhibited comparable compression in both bone qualities.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.067
Threshold uncertainty score0.372

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.093
GPT teacher head0.396
Teacher spread0.303 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueMedicineSame topicBone fractures and treatmentsFrench-language works237,207