MétaCan
Menu
Back to cohort
Record W2332244691 · doi:10.1097/bpo.0000000000000195

Validity and Reliability of the iPhone to Measure Rib Hump in Scoliosis

2014· article· en· W2332244691 on OpenAlexaff
Frédéric Balg, Mathieu Juteau, Chantal Theoret, Amy Svotelis, Guillaume Grenier

Bibliographic record

VenueJournal of Pediatric Orthopaedics · 2014
Typearticle
Languageen
FieldMedicine
TopicScoliosis diagnosis and treatment
Canadian institutionsUniversité de Sherbrooke
Fundersnot available
KeywordsMedicineIdiopathic scoliosisIntraclass correlationScoliosisReliability (semiconductor)Cobb anglePhysical therapyOrthodonticsReproducibilitySurgeryMathematicsStatisticsPsychometrics

Abstract

fetched live from OpenAlex

STUDY DESIGN: This was a prospective blinded validity and reliability analysis. OBJECTIVE: The aim of this study was validation and reliability evaluation of the Scoligauge iPhone app. BACKGROUND: The scoliometer is used to clinically measure the rib hump in scoliosis as a means to evaluate the axial trunk rotation. The increasing availability of smartphone with built-in accelerometer led to the development of a vast number of applications to measure angles. Of these, the Scoligauge mimics a scoliometer. The aim of this study was to compare the validity of the Scoligauge iPhone application without an associated adapter with the traditional scoliometer and to test the reliability of the application in a clinical setting. METHODS: Two observers measured the rib hump deformity on 34 consecutive patients with idiopathic scoliosis with an average Cobb angle of 24.2 ± 13.5 degrees (range, 4 to 65 degrees). Measurements were made with an iPhone without the adapter and with a scoliometer. The validity as well as the interobserver and intraobserver reliability were calculated using the intraclass coefficient (ICC) and the Bland-Altman test. RESULTS: The mean difference between the scoliometer and the Scoligauge application was 0.4 degrees [95% confidence interval (CI) of ± 3.1 degrees] with an ICC of 0.947 (P < 0.001). The intraobserver and interobserver ICC were 0.961 (P < 0.001) and 0.901 (P < 0.001), respectively. The mean intraobserver difference was 0.0 degrees (95% CI of ± 2.7 degrees) and the mean interobserver difference was 0.1 degrees (95% CI of ± 4.4 degrees). CONCLUSIONS: The intraobserver and interobserver reliability of the Scoligauge iPhone app, as well as its validity compared with the scoliometer, are excellent. The mean differences between measurements are small and clinically not significant. Thus, the Scoligauge application is valid for clinical evaluation even without special adapter. LEVEL OF EVIDENCE: Level I (Diagnostic Study).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.341

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.025
GPT teacher head0.276
Teacher spread0.251 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations34
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Pediatric OrthopaedicsSame topicScoliosis diagnosis and treatmentFrench-language works237,207