To the Editor.—Carotenoids are brightly colored plant pigments that are essential for several metabolic functions including cell growth regulation and immune response. Carotene (previtamin A) is a slowly absorbed, fat-soluble, carotenoid pigment normally present in the diet. Serum carotene levels are used to determine the possibility of absorption defects that can lead to malabsorption. Decreased carotene levels are seen in several malabsorption syndromes, including, but not limited to, some pancreatic diseases, sprue, post–small intestine resection, and celiac disease.1Fat-soluble vitamins, such as carotene, are generally considered highly unstable when exposed to light, air, and ambient temperature.2 Therefore, serum carotene samples that are referred to core laboratories from satellite sites are required to be shipped frozen and protected from light at all times of handling and analysis. Recent studies indicate that fat-soluble vitamins, including carotene concentrations in whole blood, change insignificantly when stored for up to 7 days at room temperature in dark or light conditions; however, stability data for serum carotene remain scarce.3,4We prepared 5 different serum pools from healthy adult volunteers and from 7-day-old leftover laboratory specimens within our laboratory. Aliquots of 600 µL from each pool were maintained at various light and temperature conditions: room temperature–dark, room temperature–light, refrigerated-dark, refrigerated-light, frozen (−30°C)-dark, and frozen (−70°C)-dark for durations of 1 to 14 days. At the end of the timed conditions (Day 0, 1, 3, 7, 10, 14), the appropriate aliquots were removed and stored at −70°C until analysis. Serum carotene was then extracted with petroleum ether and analyzed using spectrophotometry at a wavelength of 440 nm. The procedure was performed under minimal lighting conditions. The stability of carotene under each storage condition was determined by calculating the percentage change in concentration from those of day 0, then calculating the mean percentage change (and standard error of the mean) of the 5 pools at each time point. Data were analyzed by 1-way analysis of variance using SPSS (Chicago, Illinois) and a P value < .05 was considered statistically significant.The analytic imprecision of this carotene assay is 6.6% at levels of 96.6 µg/dL (1.8 µmol/L) and 155.7 µg/dL (2.9 µmol/L). Carotene levels of the 5 serum pools ranged from 134.2 µg/dL (2.50 µmol/L) to 230.9 µg/dL (4.3 µmol/L). Serum stored at −70°C for 14 days (the end of study controls) demonstrated a minimal average change of only 3.04% compared with those measured freshly at day 0. Samples stored in the room temperature–light condition for 10 and 14 days demonstrated a significant decrease of 24.5% (P = .02) and 28.3% (P = .01) respectively in carotene levels when compared with the end-of-study controls. Except for room temperature, storage conditions did not induce clinically significant changes in serum carotene (Table).In conclusion, serum carotene levels are stable when stored at 4°C (in dark or light) or in the freezer for up to 14 days. Carotene stability is also acceptable at room temperature–dark for 7 days or room temperature–light for 3 days. In addition, repeated freezing to −70°C and thawing has been demonstrated to have no significant effects (less than 1% per freeze-thaw cycle) on the serum and plasma carotene concentrations.5 These results allow for less stringent storage, shipping, and handling conditions for serum carotene specimens.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Research integrity, Insufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.664
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0020.000
Bibliometrics0.0000.000
Science and technology studies0.0000.002
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.003
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.030
GPT teacher head0.313
Teacher spread0.283 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueArchives of Pathology & Laboratory MedicineSame topicClinical Laboratory Practices and Quality ControlFrench-language works237,207