MétaCan
Menu
Back to cohort
Record W2333637106 · doi:10.1021/jf404880v

Total Phospholipids in Edible Oils by In-Vial Solvent Extraction Coupled with FTIR Analysis

2014· article· en· W2333637106 on OpenAlexaff
Xianghe Meng, Qin Ye, Qiuyue Pan, Yang Ding, Min Wei, Yun Liu, F.R. van de Voort

Bibliographic record

VenueJournal of Agricultural and Food Chemistry · 2014
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicMetabolomics and Mass Spectrometry Studies
Canadian institutionsMcGill University
Fundersnot available
KeywordsFourier transform infrared spectroscopyChemistryChromatographyExtraction (chemistry)SolventVegetable oilAnalytical Chemistry (journal)Organic chemistry

Abstract

fetched live from OpenAlex

A simple procedure for the determination of total phospholipids (TPL) in edible oils was developed by combining a single-step, in situ methanol/acetonitrile (MeOH/ACN) extraction of the oil sample followed by Fourier transform infrared (FTIR) spectroscopic analysis of the extract. Spectral analysis of extracts in a 25 μm CaF 2 cell obtained using 1:1 MeOH/ACN added to oil in a 2:1 ratio indicated that measurements made using only the asymmetric phosphate diester PO 2 – stretching band at 1243 cm –1 in second-derivative spectra were sufficient for the accurate measurement of TPL with minimal coextracted triglyceride interferences being encountered. FTIR calibration spectra were devised using only phosphatidylcholine (PC) as a representative phospholipid standard, covering a range of 0–50000 μg/g TPL and spiked into 1:1 MeOH/ACN, capable of tracking the added PC with an SD of <200 μg/g. The FTIR method was initially validated using model PC-spiked degummed canola oil and subsequently with commercial crude and refined soy and rapeseed oils as well as a lecithin tablet with the FTIR TPL predictions compared to those of the AOCS Ca 12-55 molybdenate method. The FTIR method tracked the AOCS results well, being somewhat more reproducible than the reference method (±3.2 vs ±4.9%), which limited its accuracy relative to the AOCS reference procedure (±2.2%). The simple in-vial solvent extraction procedure, followed by FTIR analysis of the extract, is a simple, efficient, and rapid procedure that is also amenable to automation using an autosampler-equipped FTIR if multiple samples are to be analyzed.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.003
GPT teacher head0.197
Teacher spread0.194 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations26
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Agricultural and Food ChemistrySame topicMetabolomics and Mass Spectrometry StudiesFrench-language works237,207