MétaCan
Menu
Back to cohort
Record W2334740560 · doi:10.1021/ac300840b

Infrared Matrix-Assisted Laser Desorption/Ionization Orthogonal-Time-of-Flight Mass Spectrometry Employing a Cooling Stage and Water Ice As a Matrix

2012· article· en· W2334740560 on OpenAlexfundno aff
Alexander Pirkl, Jens Soltwisch, Felix Draude, Klaus Dreisewerd

Bibliographic record

VenueAnalytical Chemistry · 2012
Typearticle
Languageen
FieldChemistry
TopicMass Spectrometry Techniques and Applications
Canadian institutionsnot available
FundersUniversity of Manitoba
KeywordsChemistryMass spectrometryAnalytical Chemistry (journal)DesorptionMatrix (chemical analysis)Liquid nitrogenIonizationFluenceLaserTime-of-flight mass spectrometryChromatographyIonOpticsOrganic chemistry

Abstract

fetched live from OpenAlex

Although water ice has been utilized in the past as a matrix for infrared matrix-assisted laser desorption/ionization mass spectrometry (IR-MALDI-MS), it has not found a wider use due to limitations in the analytical performance and technical demands on the employment of the necessary cooling stage. Here, we developed a temperature-controlled sample stage for use with an orthogonal time-of-flight mass spectrometer (MALDI-o-TOF-MS). The stage utilizes a combination of liquid nitrogen cooling and counterheating with a Peltier element. It allows adjustment of the sample temperature between ~-120 °C and room temperature. To identify optimal irradiation conditions for IR-MALDI with the water ice matrix, we first investigated the influence of excitation wavelength, varied between 2.7 and 3.1 μm, and laser fluence on the signal intensities of molecular substance P ions. These data suggest the involvement of transient melting of the ice during the laser pulse and primary energy deposition into liquid water. As a consequence, the best analytical performance is obtained at a wavelength corresponding to the absorption maximum of liquid water of about 2.94 μm. The current data significantly surpass the previously reported analytical features. The particular softness of the method is, for example, exemplified by the analysis of noncovalently bound holo-myoglobin and of ribonuclease B. This is also the first report demonstrating the analysis of an IgG monoclonal antibody (MW ~ 150 kDa) from a water ice matrix. Untypical for MALDI-MS, high charge states of multiply protonated species were moreover observed for some of the investigated peptides and even for lacto-N-fucopentaose II oligosaccharides. Using water ice as matrix is of particular interest for MALDI MS profiling and imaging applications since matrix-free spectra are produced. The MS and tandem MS analysis of metabolites directly from frozen food samples is demonstrated with the example of a strawberry fruit.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Insufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.018
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0190.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.279
Teacher spread0.267 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations46
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueAnalytical ChemistrySame topicMass Spectrometry Techniques and ApplicationsFrench-language works237,207