Abstract

fetched live from OpenAlex

OBJECTIVE: To investigate brain radiation dose in complex cases arising from two stereotactic linear accelerator designs and to present a method for comparing brain dose to published data. METHODS: Two head designs were considered: Beam Modulator (BM) and Agility (AG). 12 patients treated on BM were replanned with AG. Planning objectives were: minimize brain dose and satisfy target coverage and organs at risk dose constraints. Each of the 36 targets was analyzed for conformality index (CI Paddick), gradient index (GI) and homogeneity index (HI). Total volume of tissue receiving 80% (V80) of the prescription dose down to 25% (V25) was evaluated. Similarly the volume of brain minus planning target volume receiving 80% (BMP80) down to 25% (BMP25) was evaluated. The mean brain dose and BMP dose were also evaluated. System differences were statistically evaluated using Wilcoxon signed-rank test. Power-law models for total volume (V) and brain minus planning target volumes (BMP) were generated based on BM data. RESULTS: The median CI Paddick was 0.74 and 0.76 for BM and AG, respectively (p = 0.04). The median GI was 5.5 and 6.1 (p < 0.01) and the median HI was 1.17 and 1.16 for BM and AG, respectively (p < 0.01). Neither V or BMP receiving doses of 80% down to 40% exhibited statistically significant difference between the two systems, whereas the volume of brain minus PTV receiving 25% (BMP25) was weakly different (p = 0.02). AG exhibited a lower mean BMP dose (4.1 Gy) than BM (4.6 Gy) (p < 0.01). Power-law models for V/BMP showed excellent (R(2) > 0.80) agreement for the dose levels studied and comparable results with published data. CONCLUSION: Treatment plans of equivalent quality were attained with AG compared with BM. ADVANCES IN KNOWLEDGE: The AG system involves a novel collimation design. The present article demonstrates equivalent or improved brain dose for complex, multitarget cases using AG vs an older stereotactic system.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.266
Threshold uncertainty score0.529

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.030
GPT teacher head0.310
Teacher spread0.280 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueBritish Journal of RadiologySame topicAdvanced Radiotherapy TechniquesFrench-language works237,207