MétaCan
Menu
Back to cohort
Record W2371422562

DIFFERENCE IN THE MICROMOTION PREDICTED BY FINITE ELEMENT ANALYSIS WHEN PRESS-FIT AND CONTACT OR PRESS-FIT AND GAP IS ACHIEVED AFTER SURGERY

2016· article· en· W2371422562 on OpenAlexaff
M. Reimeringer, N. Nuño

Bibliographic record

VenueEspace ÉTS (ETS) · 2016
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsÉcole de Technologie Supérieure
Fundersnot available
KeywordsMaterials scienceContact areaCancellous boneFinite element methodIsotropyBiomedical engineeringHomogeneousFixation (population genetics)ChemistrySurgeryComposite materialOpticsMedicineStructural engineeringMathematicsEngineeringPhysics
DOInot available

Abstract

fetched live from OpenAlex

Introduction Cementless stems are fixed to the surrounding bone by means of mechanical press-fit. Short-, mid-, and long term outcomes are good for this type of fixation despite that only a part of the stem surface is in contact with the surrounding bone. Several studies show that the contact ratio achieved after surgery between the stem and the surrounding bone ranged between 15% and 60%. Then, only a part of the stem-bone interface presents a press-fit. The rest of the stem-bone interface is only in contact or presents an interfacial gap inherent to the surgical technique. Therefore, this study aimed to investigate the difference in the primary stability of a cementless stem between a press-fit combined with contact and a press-fit combined with gap achieved after the surgery. Materials & Methods A finite element study was carried out on a composite bone implanted with a femoral stem and subjected to physiological loading simulating stair climbing [1]. All materials were defined as isotropic homogeneous. The stem-bone interface was divided into 4 areas: the superior plasma spray, the inferior plasma spray, the polished surface of the stem in contact with the cancellous bone, and the plasma spray surface of the stem in contact with the cortical bone. Each contact area can be either in contact with a press-fit, either in contact without press-fit or can present a gap. This result in a total of 28 cases: 14 where there is a press-fit combined with contact and 14 cases where there is a press-fit combined with gap. Results When 1 press-fit is combined with 3 contacts, the average micromotion reaches 26µm. The average micromotion increases up to 47µm (+45%) when 1 press-fit is combined with 3 gaps. The detailed results can be seen on Figure 1. When 2 press-fits are combined with 2 contacts, the average micromotion reaches 28µm. The average micromotion increases up to 36µm (+29%) when 2 press-fit are combined with 2 gaps. The detailed results can be seen on Figure 2. When 3 press-fits are combined with 1 contact, the average micromotion reaches 31µm. The average micromotion increases up to 34µm (+9%) when 3 press-fits are combined to 1 gap. The detailed results can be seen on Figure 3. Discussion As expected, micromotion predicted when press-fit is combined with contact is lower than when press-fit is combined with gap. However, the average micromotion increases with the increase of press-fit when combined with contact (from 26µm to 31µm (+19%)). The increase of the press-fit area combined with contact lead to a slightly increase of the micromotion. Conversely, the average micromotion decreases with the increase of press-fit when combined with gap (from 47µm to 34µm (−28%)). This is due to the increase of the press-fit area, and then the gap has a lesser effect. This study also shows that the difference in the micromotion between press-fit when combined with contact and press-fit when combined with gap decreases with the increase of the press-fit.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.024
Threshold uncertainty score0.600

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.259
Teacher spread0.231 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueEspace ÉTS (ETS)Same topicOrthopaedic implants and arthroplastyFrench-language works237,207