MétaCan
Menu
Back to cohort
Record W2398702431

Ultrasound and a new videobronchoscopic technique to measure the subglottic diameter.

2000· article· en· W2398702431 on OpenAlexaffabout
Chantal Giguère, John J. Manoukian, Yves Patenaude, Robert W. Platt

Bibliographic record

VenuePubMed · 2000
Typearticle
Languageen
FieldMedicine
TopicOtolaryngology and Infectious Diseases
Canadian institutionsMontreal Children's Hospital
Fundersnot available
KeywordsCalipersMedicineLumen (anatomy)UltrasoundLimits of agreementNuclear medicineConfidence intervalMean differenceSubglottisBiomedical engineeringLarynxSurgeryGlottisRadiologyMathematicsInternal medicine
DOInot available

Abstract

fetched live from OpenAlex

OBJECTIVE: The aim of this study was to evaluate ultrasound (US) and a new videobronchoscopic (VB) technique in the measurement of the subglottic lumen diameter. DESIGN: This blind prospective animal study of 62 recently sacrificed rabbits was conducted at the Montreal Children's Hospital. METHODS: Three different diameter measurements of the subglottis were assessed using B-mode US on each intact animal. The same diameter measurements, as well as a fourth, were estimated with a VB measuring technique. Finally, the subglottic area was surgically exposed allowing for direct caliper measurements of all four corresponding diameters. All three US measurements on each of the 62 rabbits and all four VB measurements on each of the 60 rabbits were compared with the gold standard corresponding caliper measurements. RESULTS: Statistical analysis revealed strikingly convergent values in subglottic lumen diameter measurements using US and calipers. The mean difference between these methods for all 186 observations was 0.11 mm. With 95% confidence, the maximum discordance was less than 0.30 mm on the smallest evaluated lumen. Convergent values were also demonstrated in subglottic lumen diameter measurements using VB and calipers. The mean difference between these methods for all 240 observations was 0.16 mm. With 95% confidence, the maximum discordance was less than 0.37 mm on the smallest evaluated lumen. Pearson's correlation coefficient supported a strong and positive relationship between US and caliper measurements as well as VB and caliper measurements. Simple linear regression model indicated that the subglottic lumen diameter could be predicted by both US and our VB technique. CONCLUSION: This work represents the first attempt to validate B-mode US and a VB technique as measuring tools for the subglottic lumen diameter. Our results have clearly shown that both methods are precise measuring modalities for this purpose. With further studies, these two objective methods of measuring the subglottic diameter could be adopted universally. The precise knowledge of this diameter could help physicians recognize and describe the severity of a narrowed lumen. Reporting results in such a standardized fashion, by either US or VB, could facilitate communication among clinicians and institutions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.345
Threshold uncertainty score0.396

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.233
Teacher spread0.213 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2000
Admission routes2
Has abstractyes

Explore more

Same venuePubMedSame topicOtolaryngology and Infectious DiseasesFrench-language works237,207