MétaCan
Menu
Back to cohort
Record W2402312689 · doi:10.1002/jmri.25180

Assessment of the precision and reproducibility of ventricular volume, function, and mass measurements with ferumoxytol‐enhanced 4D flow MRI

2016· article· en· W2402312689 on OpenAlexaff
Kate Hanneman, Aya Kino, Joseph Y. Cheng, Marcus T. Alley, Shreyas Vasanawala

Bibliographic record

VenueJournal of Magnetic Resonance Imaging · 2016
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsToronto General HospitalUniversity of Toronto
FundersNational Institute of Biomedical Imaging and Bioengineering
KeywordsSteady-state free precession imagingMedicineIntraclass correlationLimits of agreementReproducibilityNuclear medicineEjection fractionCardiologyMagnetic resonance imagingInternal medicineRadiologyHeart failureMathematics

Abstract

fetched live from OpenAlex

PURPOSE: To compare the precision and interobserver agreement of ventricular volume, function, and mass quantification by 3D time-resolved (4D) flow MRI relative to cine steady-state free precession (SSFP). MATERIALS AND METHODS: With Institutional Research Board approval, informed consent, and HIPAA compliance, 22 consecutive patients with congenital heart disease (CHD) (10 males, 6.4 ± 4.8 years) referred for 3T ferumoxytol-enhanced cardiac MRI were prospectively recruited. Complete ventricular coverage with standard 2D short-axis cine SSFP and whole chest coverage with axial 4D flow were obtained. Two blinded radiologists independently segmented images for left ventricular (LV) and right ventricular (RV) myocardium at end systole (ES) and end diastole (ED). Statistical analysis included linear regression, analysis of variance (ANOVA), Bland-Altman (BA) analysis, and intraclass correlation (ICC). RESULTS: Significant positive correlations were found between 4D flow and SSFP for ventricular volumes (r = 0.808-0.972, P < 0.001), ejection fraction (EF) (r = 0.900-928, P < 0.001), and mass (r = 0.884-0.934, P < 0.001). BA relative limits of agreement for both ventricles were between -52% to 34% for volumes, -29% to 27% for EF, and -41% to 48% for mass, with wider limits of agreement for the RV compared to the LV. There was no significant difference between techniques with respect to mean square difference of ED-ES mass for either LV (F = 2.05, P = 0.159) or RV (F = 0.625, P = 0.434). Interobserver agreement was moderate to good with both 4D flow (ICC 0.523-0.993) and SSFP (ICC 0.619-0.982), with overlapping confidence intervals. CONCLUSION: Quantification of ventricular volume, function, and mass can be accomplished with 4D flow MRI with precision and interobserver agreement comparable to that of cine SSFP. J. Magn. Reson. Imaging 2016;44:383-392.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.381
Threshold uncertainty score0.182

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.285
Teacher spread0.272 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations46
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Magnetic Resonance ImagingSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207