MétaCan
Menu
Back to cohort
Record W2405030509 · doi:10.1177/0310057x1003800512

Continuous Central Venous Oxygen Saturation Monitoring under Varying Physiological Conditions in an Animal Model

2010· article· en· W2405030509 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueAnaesthesia and Intensive Care · 2010
Typearticle
Languageen
FieldMedicine
TopicHemodynamic Monitoring and Therapy
Canadian institutionsChild and Family Research InstituteBC Children's HospitalUniversity of British Columbia
Fundersnot available
KeywordsMedicineAnesthesiaInferior vena cavaCatheterSuperior vena cavaArterial catheterPulse oximetryBlood volumeBlood pressureSurgeryInternal medicine

Abstract

fetched live from OpenAlex

We compared saturations from a paediatric central venous oximetry catheter with co-oximetry values with changes in drug infusions, intravascular blood volume and hypoxia in an animal model. Piglets (large white) were anaesthetised, intubated and mechanically ventilated. PediaSat oximetry catheters were placed in the superior vena cava via jugular vein cut-down and in the inferior vena cava percutaneously via the femoral vein. A carotid arterial catheter was placed via cut-down for blood sampling and pressure monitoring. Anaesthesia was maintained with continuous thiopentone and supplemental morphine. Haemodynamics (heart rate, mean arterial blood, central venous pressure), fibreoptic ScvO2 (ScvO2-inferior) from inferior vena cava, fibreoptic ScvO2 (ScvO2-superior) from superior vena cava and blood gas oximetry (ScvO2-co-ox) were measured simultaneously at predetermined intervals during increasing adrenaline and sodium nitroprusside infusions and during increasing hypoxia and hypovolaemia. There was good agreement of both superior vena cava and inferior vena cava ScvO2 catheters with co-oximetry during adrenaline and sodium nitroprusside infusions. During the hypoxia study there was good agreement between the co-oximeter to ScvO2-superior catheter but poor agreement with to the inferior vena cava catheter samples. In the hypovolaemic phase of the experiment there was good agreement between the measured co-oximetry value and ScvO2-superior catheter until the mean blood pressure reached 43 mmHg. The oximetry catheter is capable of identifying changes in ScvO2 under physiological conditions usually encountered in clinical medicine but was less accurate at the extremes of physiology and when placed in the inferior vena cava catheter especially during hypovolaemia and hypoxia.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.855
Threshold uncertainty score0.463

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.027
GPT teacher head0.304
Teacher spread0.277 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it