CarboMedics mechanical prosthesis: performance at eight years.

2000· article· en· W2407867537 on OpenAlexaff
W.R. Eric Jamieson, Guy Fradet, Robert T. Miyagishima, Charmaine Henderson, Regina Brownlee, J Zhang, Eva Germann

Bibliographic record

VenuePubMed · 2000
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsSt. Paul's Hospital
Fundersnot available
KeywordsMedicineProsthesisMitral valve replacementThrombosisCardiologyValve replacementAortic valve replacementSurgeryMechanical valveInternal medicineAortic valveSurvival rateMitral valveStenosis
DOInot available

Abstract

fetched live from OpenAlex

BACKGROUND AND AIM OF THE STUDY: The bileaflet St. Jude Medical mechanical prosthesis has been implanted for over 20 years. The purpose of this study was to evaluate the clinical performance of the bileaflet CarboMedics (CM) prosthesis, which was introduced in 1986. METHODS: The CM prosthesis was implanted in 1,258 patients (709 males, 549 females; mean age 60.9 +/- 12.3 years) between 1989 and 1997. The prosthesis distribution was aortic valve replacement (AVR) 613; mitral valve replacement (MVR) 447; and multiple replacement (MR) 231. Coronary artery bypass (CAB) was performed in 334 (26.6%) patients; previous procedures had been performed in 346 (27.5%). The age distribution was <60 years (n = 527), 61-70 years (n = 424) and >70 years (n = 307). Risk factors assessed were age or age groups, gender, CAB, previous surgery, rhythm, valve position, status and NYHA functional class. The total follow up was 4,765.0 patient-years (pt-yr), and was 98.4% complete. RESULTS: The early mortality rate was 5.6% (AVR 4.8%, MVR 3.7%, MR 11.5%). The late mortality rate was 3.7%/pt-yr (n = 174), and valve-related mortality 1.1%/pt-yr (n = 50). The total thromboembolism (TE) rate was 4.1%/pt-yr (n = 195) (p = NS by valve position); the major TE rate was 1.9%/pt-yr and fatal TE rate 0.31%/pt-yr (n = 15). The valve thrombosis rate was 0.31%/pt-yr (n = 15; 11 MVR, four MR). The fatal thrombosis rate was 0.06%/pt-yr (n = 3; two MVR, one MR). The hemorrhage rate was 2.7%/pt-yr (n = 128) and fatal hemorrhage rate 0.4%/pt-yr (n = 20). The reoperation rate was 1.0%/pt-yr (n = 46), fatal 0.1%/pt-yr (n = 5). The actuarial freedom from overall TE at eight years was 77.3 +/- 2.8%; major TE 88.5 +/- 1.6%, and hemorrhage 76.4 +/- 3.2% (all p = NS by valve position). There were no independent predictors of overall TE and TE exclusion of early events. The only predictor for TE major was status (emergency > urgent > elective). The actuarial freedom from valve-related mortality at eight years was 91.4 +/- 1.8% (p = NS by position) (actual freedom 93.0 +/- 1.3%). The actuarial freedom from valve-related reoperation was 91.1 +/- 2.4% (p <0.05; AVR > MVR and MR, MVR > MR) (actual freedom 92.2 +/- 2.7%). Overall survival rate at eight years was 68.2 +/- 2.3% (p <0.05; AVR > MVR and MR, MVR > MR). CONCLUSION: The clinical performance of the CarboMedics mechanical prosthesis is satisfactory when implanted in the mitral, aortic and multiple positions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.245
Teacher spread0.233 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations29
Published2000
Admission routes1
Has abstractyes

Explore more

Same venuePubMed→Same topicCardiac Valve Diseases and Treatments→French-language works237,207→