MétaCan
Menu
Back to cohort
Record W2408679039 · doi:10.1093/jaoac/89.4.1158

An Accurate and Reproducible Method for the Quantitative Analysis of Isoflavones and Their Metabolites in Rat Plasma Using Liquid Chromatography/Mass Spectrometry Combined with Photodiode Array Detection

2006· article· en· W2408679039 on OpenAlexafffund
Estatira Sepehr, Patrick Robertson, G. Sarwar Gilani, Gerard M. Cooke, Benjamin P.‐Y. Lau

Bibliographic record

VenueJournal of AOAC International · 2006
Typearticle
Languageen
FieldMedicine
TopicPhytoestrogen effects and research
Canadian institutionsUniversity of OttawaHealth Canada
FundersHealth CanadaU.S. Food and Drug Administration
KeywordsChromatographyIsoflavonesMass spectrometryPhotodiodeChemistryLiquid chromatography–mass spectrometryQuantitative analysis (chemistry)Analytical Chemistry (journal)Materials scienceBiochemistryOptoelectronics

Abstract

fetched live from OpenAlex

To study the safety and potential health benefits of soy isoflavones, a rapid and simple method based on liquid chromatography combined with mass spectrometry (LC/MS) and photodiode array detector (PDA) was developed for the determination of isoflavones in rat plasma. The analytes included daidzein, genistein, glycitein, equol, 4-ethyl phenol, and biochanin A over a concentration range of 1.0-4320.0 nM using 75 microL of rat plasma. Rat plasma samples were hydrolyzed by adding an enzyme mixture from Helix pomatia containing glucuronidase and sulfatase to convert the isoflavone beta-glycosides daidzin, genistin, and glycitin to their active aglycone forms. A liquid-liquid extraction method using ethyl acetate as the extraction solvent was used to extract aglycones and the internal standards (phenolphthalein beta-D glucuronide, 4-methylumbelliferyl sulfate, and apigenin) from digested plasma samples. The extract was evaporated to dryness under a nitrogen stream, reconstituted with 0.1% formic acid in water-acetonitrile (85 + 15), and injected into a Zorbax SB-CN reversed-phase column (4.6 x 75 mm, 3.5 microm particle size). The Micromass ZQ detector was operated in the positive ion selected-ion monitoring mode. The flow rate for LC was 1.0 mL/min, with a split where 25% of the effluent was introduced into the electrospray ionization probe of the MS instrument and 75% into the PDA. The chromatographic run time was 16.0 min, with delay of 10 min/injection. The interday precision and accuracy of the standard samples were <2.6% relative standard deviation and <10% relative error, respectively. Recovery of the reported isoflavones with this method varied from 86 to 100%.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.004
Threshold uncertainty score0.021

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.003
Meta-epidemiology (narrow)0.0030.001
Meta-epidemiology (broad)0.0020.001
Bibliometrics0.0020.002
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0020.001
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0020.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.025
GPT teacher head0.354
Teacher spread0.329 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations23
Published2006
Admission routes2
Has abstractyes

Explore more

Same venueJournal of AOAC InternationalSame topicPhytoestrogen effects and researchFrench-language works237,207