MétaCan
Menu
Back to cohort
Record W2410436289 · doi:10.1089/jamp.2015.1257

Nonuniform Deposition of Pressurized Metered-Dose Aerosol in Spacer Devices

2016· article· en· W2410436289 on OpenAlexafffund
Nicholas Ogrodnik, V. D. Azzi, Elizabeth Sprigge, Sandra Fiset, Edgar Matida

Bibliographic record

VenueJournal of Aerosol Medicine and Pulmonary Drug Delivery · 2016
Typearticle
Languageen
FieldMedicine
TopicInhalation and Respiratory Drug Delivery
Canadian institutionsCarleton University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsSalbutamolDeposition (geology)AerosolTurbulenceVolumetric flow rateReynolds numberMaterials scienceMechanicsMedicineAsthmaMeteorologyGeologyPhysicsInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: Pressurized metered-dose inhalers (pMDIs) are commonly used to administer medication to patients suffering from chronic lower respiratory tract diseases such as asthma. Inhaling medication directly from a pMDI can prove difficult for some patients and, as a result, add-on devices (or spacers) have been designed to aid in the delivery of medication. Although spacers increase the percentage of medication that reaches the patient, medication will also nonsymmetrically deposit on the walls of the device and will be lost to the device itself. METHODS: The deposition of medication, salbutamol sulfate, within a large- and a small-volume spacer, has been studied through an experimental and numerical analysis. Experiments were conducted at inspiratory flow rates ranging from 30 to 60 L/min. The amount of deposition of the medication on the walls of the spacer was quantified through an application of spectrophotometry. Computational fluid dynamics was used to quantify the deposition numerically. Simulations were conducted by implementing mean flow and turbulent tracking of particles using unsteady Reynolds-averaged Navier-Stokes (URANS) equations with a shear stress transport turbulence model. Regions of deposition are of interest, as well as how the method of deposition varied for different inhalation flow rates. RESULTS AND CONCLUSIONS: spacers was found to be greater in the lower half as opposed to the upper half of the spacer due to a downward spray angle. With an increased flow rate, these spacers demonstrated a slight increase in medication delivered to the inline filter, which is analogous to that reaching the patient, and an increase in distal deposition. For the numerical analysis, the results indicated that inertial impaction is the most likely method of deposition for the Volumatic spacer, and turbulence is more likely to cause deposition in the OptiChamber spacer.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.202
Threshold uncertainty score0.563

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.267
Teacher spread0.246 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2016
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Aerosol Medicine and Pulmonary Drug DeliverySame topicInhalation and Respiratory Drug DeliveryFrench-language works237,207