MétaCan
Menu
Back to cohort
Record W2410619404 · doi:10.1021/acs.analchem.5b01077

Cetyltrimethylammonium Bromide-Coated Fe<sub>3</sub>O<sub>4</sub> Magnetic Nanoparticles for Analysis of 15 Trace Polycyclic Aromatic Hydrocarbons in Aquatic Environments by Ultraperformance, Liquid Chromatography With Fluorescence Detection

2015· article· en· W2410619404 on OpenAlexafffund
Hao Wang, Xiaoli Zhao, Wei Meng, Peifang Wang, Fengchang Wu, Zhi Tang, Xuejiao Han, John P. Giesy

Bibliographic record

VenueAnalytical Chemistry · 2015
Typearticle
Languageen
FieldChemistry
TopicAnalytical chemistry methods development
Canadian institutionsUniversity of Saskatchewan
FundersState Administration of Foreign Experts AffairsNational Natural Science Foundation of ChinaCanada Research Chairs
KeywordsChemistryDetection limitSolid phase extractionTap waterExtraction (chemistry)AdsorptionSorbentBromideChromatographyEnvironmental chemistryEnrichment factorWastewaterTrace AmountsInorganic chemistry

Abstract

fetched live from OpenAlex

Accurate determination of polycyclic aromatic hydrocarbons (PAHs) in surface waters is necessary for protection of the environment from adverse effects that can occur at concentrations which require preconcentration to be detected. In this study, an effective solid phase extraction (SPE) method based on cetyltrimethylammonium bromide (CTAB)-coated Fe3O4 magnetic nanoparticles (MNPs) was developed for extraction of trace quantities of PAHs from natural waters. An enrichment factor of 800 was achieved within 5 min by use of 100 mg of Fe3O4 MNPs and 50 mg of CTAB. Compared with conventional liquid-liquid extraction (LLE), C18 SPE cartridge and some newly developed methods, the SPE to determine bioaccessible fraction was more convenient, efficient, time-saving, and cost-effective. To evaluate the performance of this novel sorbent, five natural samples including rainwater, river waters, wastewater, and tap water spiked with 15 PAHs were analyzed by use of ultraperformance, liquid chromatography (UPLC) with fluorescence detection (FLD). Limits of determination (LOD) of PAHs (log Kow ≥ 4.46) ranged from 0.4 to 10.3 ng/L, with mean recoveries of 87.95 ± 16.16, 85.92 ± 10.19, 82.89 ± 5.25, 78.90 ± 9.90, and 59.23 ± 3.10% for rainwater, upstream and downstream river water, wastewater, and tap water, respectively. However, the effect of dissolved organic matter (DOM) on recovery of PAHs varied among matrixes. Because of electrostatic adsorption and hydrophobicity, DOM promoted adsorption of Fe3O4 MNPs to PAHs from samples of water from the field. This result was different than the effect of DOM under laboratory conditions. Because of competitive adsorption with the site of action on the surface of Fe3O4 MNPs for CTAB, recoveries of PAHs were inversely proportional to concentrations of Ca(2+) and Mg(2+). This novel sorbent based on nanomaterials was effective at removing PAHs at environmentally relevant concentrations from waters containing relevant concentrations of both naturally occurring organic matter and hardness metals.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.043
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.003
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.234
Teacher spread0.221 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations59
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueAnalytical ChemistrySame topicAnalytical chemistry methods developmentFrench-language works237,207