MétaCan
Menu
Back to cohort
Record W2412276345

Keynote: Simulation of Bioresorbable Scaffold and Metallic Stent Deployment in Concentric and Eccentric Coronary Lesion Models

2016· article· en· W2412276345 on OpenAlexaff
Chad Abunassar

Bibliographic record

VenueThe 7th International Conference on Computational Methods (ICCM2016) · 2016
Typearticle
Languageen
FieldMedicine
TopicCoronary Interventions and Diagnostics
Canadian institutionsAbbott (Canada)
Fundersnot available
KeywordsStentEccentricBioresorbable scaffoldBiomedical engineeringImplantConcentricMaterials scienceArteryRestenosisScaffoldMedicineElastic recoilBiomechanicsStructural engineeringCardiologySurgeryPercutaneous coronary interventionAnatomyInternal medicineMyocardial infarctionEngineeringGeometry
DOInot available

Abstract

fetched live from OpenAlex

The introduction of bioresorbable vascular scaffolds has provided a new option for the treatment of coronary artery disease with the promise of improved long-term vessel behavior when compared to permanent metallic drug eluting stents. While this long term benefit holds great promise, further characterization is required to understand the impact of design changes and material differences between these two implant types. In this study, finite element analysis was used to compare the head-to-head deployment mechanics of a bioresorbable vascular scaffold (Absorb, Abbott Vascular) and a cobalt chromium metallic drug eluting stent (Xience V, Abbott Vascular) with respect to the predicted levels of recoil and stress induced in the vessel wall. Crimping and deployment of each implant were modeled in Abaqus (Dassault Systems Inc,) and incorporated constitutive behaviors for both polymeric and metallic materials as well as for arterial wall layers and plaque. Plaque morphology was also modeled as both concentric and eccentric to clarify differences in implantation behavior between both implant types in these two lesion scenarios. In the simulations performed, Absorb showed a higher degree of recoil than Xience V, which suggests that balloon post-dilatation is important for effective treatment of tight and calcified plaques. However, the Absorb scaffold induces significantly lower stresses on the artery-plaque system, along with lower contact pressures, which can relate to improved biological response and an improved long-term clinical safety profile. When comparing deployment in both concentric and eccentric plaques, deployment in an eccentric plaque results in non-uniform vessel expansion and is associated with considerably higher levels of stress in the media and adventitia layers of the artery wall. In these situations, the choice of implant, in terms of materials and designs, is of paramount importance. Our results imply that the benefits of Absorb scaffolds are amplified in these cases.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.010
Threshold uncertainty score0.034

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0100.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.153
GPT teacher head0.409
Teacher spread0.256 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueThe 7th International Conference on Computational Methods (ICCM2016)Same topicCoronary Interventions and DiagnosticsFrench-language works237,207