MétaCan
Menu
Back to cohort
Record W2416995348 · doi:10.1109/tns.2016.2576963

First Results From a High-Resolution Small Animal SiPM PET Insert for PET/MR Imaging at 7T

2016· article· en· W2416995348 on OpenAlexafffund
Andrew L. Goertzen, Greg Stortz, Jonathan D. Thiessen, D. Bishop, Muhammad Salman Khan, Piotr Kozłowski, F. Retière, Graham Schellenberg, Ehsan Shams, Vesna Sossi, Christopher J. Thompson

Bibliographic record

VenueIEEE Transactions on Nuclear Science · 2016
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsMcGill UniversityMontreal Neurological Institute and HospitalWinnipeg Regional Health AuthorityTRIUMFLawson Health Research InstituteWestern UniversityUniversity of ManitobaUniversity of British ColumbiaHealth Sciences Centre
FundersNatural Sciences and Engineering Research Council of CanadaMitacsUniversity of ManitobaManitoba Health Research Council
KeywordsDetectorSilicon photomultiplierPhysicsScintillatorOptics

Abstract

fetched live from OpenAlex

We present the initial results from a small animal PET insert designed to be operated inside a 7T MRI. The insert fits within the 114 mm inner diameter of the Bruker BGA-12S gradient coil while accommodating the Bruker 35 mm volume RF coil (outer diameter 60 mm), both used in the Bruker 70/20 MRI systems. The PET insert is a ring comprising 16 detectors. Each detector has a dual-layer offset (DLO) lutetium-yttrium oxyorthsilicate (LYSO) scintillator array read out by two SensL SPMArray4B SiPM arrays. The DLO scintillator has bottom (top) layers of:$22\times 10$($21 \times 9$) crystals of size$1.2 \times 1.2 \times 6$(4) mm3for a total of 409 crystals per block, providing an axial extent of 28.17 mm. The detector outputs are multiplexed to four signals using a custom readout board and digitized using the OpenPET data acquisition platform. The detector flood images successfully resolve over 99% of the crystals, with average energy resolution of 12.5 ± 2.0% at 511 keV. Testing of the PET system inside the MRI showed that the PET insert had no effect on MRI image homogeneity and only a small effect on echo planar images (EPI) signal to noise ratio (SNR) (-9%), with neither PET nor MRI images showing obvious artefacts. These acquisitions used the OpenPET operating in “oscilloscope mode” with USB2.0 interface, allowing a maximum total singles event rate of 280 kcps, strongly limiting the count rate capabilities of the system. The PET radial spatial resolution (as measured with a22Na point source and FBP-3DRP reconstruction) is 1.17 mm at the centre, degrading to 1.86 mm at a 15 mm radial offset. Simultaneous phantom and mouse PET/MR imaging produced good quality images that were free of any obvious artefacts.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.007
Threshold uncertainty score0.023

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0070.005

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.275
Teacher spread0.249 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations52
Published2016
Admission routes2
Has abstractyes

Explore more

Same venueIEEE Transactions on Nuclear ScienceSame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207