Emergency Radiobioassay Method for Determination of <sup>90</sup>Sr and <sup>226</sup>Ra in a Spot Urine Sample
Bibliographic record
Abstract
A new radiobioassay method has been developed for simultaneous determination of (90)Sr and (226)Ra in a spot urine sample. The method is based on a matrix removal procedure to purify the target radionuclides from a urine sample followed by an automated high performance ion chromatographic (HPIC) separation of (90)Sr and (226)Ra and offline radiometric detection by liquid scintillation counting (LSC). A Sr-resin extraction chromatographic cartridge was used for matrix removal and purification of (90)Sr and (226)Ra from a urine sample prior to its introduction to the HPIC system. The HPIC separation was carried out through cation exchange chromatography using methanesulfonic acid (75 mM) as the mobile phase at 0.25 mL/min flow rate. The performance criteria of the method was evaluated against the American National Standard Institute ANSI/HPS N13.30-2011 standard for the root mean squared error (RMSE) of relative bias (Br) and relative precision (SB) at two different spiked activity levels. The RMSE of Br and SB for (90)Sr and (226)Ra were found to be satisfactory (≤0.25). The minimum detectable activity (MDA) of the method for (90)Sr and (226)Ra are 2 Bq/L and 0.2 Bq/L, respectively. The MDA values are at least 1/10th of the concentrations of (90)Sr (190 Bq/L) and (226)Ra (2 Bq/L) excreted in urine on the third day following an acute exposure (inhalation) that would lead to an effective dose of 0.1 Sv in the first year. The sample turnaround time is less than 8 h for simultaneous determination of (90)Sr and (226)Ra.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".