Three-Dimensional Echocardiography Compared With Computed Tomography to Determine Mitral Annulus Size Before Transcatheter Mitral Valve Implantation
Bibliographic record
Abstract
BACKGROUND: Previously, through the use of computed tomography (CT), it has been proposed that D-shaped versus saddle-shaped mitral annulus (MA) segmentation is more biomechanically appropriate to determine transcatheter mitral valve implantation size and eligibility. METHODS AND RESULTS: Forty-one patients with severe mitral regurgitation being considered for transcatheter mitral valve implantation who had undergone cardiac CT and 3-dimensional transesophageal echocardiography (3D-TEE) were retrospectively evaluated. A standardized segmentation protocol for the D-shaped MA was developed using Philips Q-Laboratory mitral valve quantification software. MA dimensions were compared using Spearman's rank correlation and Bland-Altman analysis. Inter- and intraobserver agreement was quantified by intraclass correlation coefficient and Bland-Altman analysis. Mean age was 77±14 years; 71% male (n=29); mitral regurgitation pathogenesis was functional in 54% (n=22) and myxomatous in 46% (n=19). Mean MA area and circumference by 3D-TEE and CT were 11.3±2.7 versus 11.4±3.0 (P=0.67) and 124.1±15.6 versus 123.9±15.5 (P=0.79), respectively, with excellent correlation between modalities (r=0.84 and r=0.86; P<0.0001) and no systematic bias (-0.20±1.8 cm(2) [-3.7 cm(2); 3.3 cm(2)], 0.37±9 mm [-18.0 mm; 17.27 mm]). Mean septal-to-lateral and inter-trigone distances by 3D-TEE and CT were 33.2±4.7 versus 32.5±4.4 (P=0.24) and 31.7±3.5 versus 32.6±3.6 (P=0.06), respectively, with good correlation (r=0.69 and r=0.71; P<0.0001) and no systematic bias (0.77±3.8 mm [-6.7 mm; 8.2 mm], -1.5±3.1 mm [-4.6 mm; 7.6 mm]). There was excellent intra- and interobserver agreement according to intraclass correlation coefficients >0.90 for all parameters. CONCLUSIONS: Similar to cardiac CT, 3D-TEE allows for D-shaped MA segmentation with no systematic difference in MA dimensions between modalities. This study supports the utilization of 3D-TEE as a complementary tool to CT assessment of the D-shaped MA to determine transcatheter mitral valve implantation size.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.017 |
| Bibliometrics | 0.000 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".