MétaCan
Menu
Back to cohort
Record W2427051955 · doi:10.1002/ccd.26527

Segmental comparison between a dedicated bifurcation stent and balloon angioplasty using intravascular ultrasound and three‐dimensional quantitative coronary angiography: A subgroup analysis of the Tryton IDE randomized trial

2016· article· en· W2427051955 on OpenAlexaff
Maik J. Grundeken, Héctor M. García‐García, Indulis Kumsārs, Maciej Lesiak, Peter Kayaert, Jo Dens, Pieter R. Stella, Robbert J. de Winter, Linda L. Laak, Philippe Généreux, Aaron V. Kaplan, Martin B. Leon, Joanna J. Wykrzykowska, Yoshinobu Onuma, Patrick W. Serruys

Bibliographic record

VenueCatheterization and Cardiovascular Interventions · 2016
Typearticle
Languageen
FieldMedicine
TopicCoronary Interventions and Diagnostics
Canadian institutionsHôpital du Sacré-Cœur de Montréal
Fundersnot available
KeywordsIntravascular ultrasoundMedicineStentConventional PCIPercutaneous coronary interventionAngioplastyBalloonStenosisLumen (anatomy)Main branchRadiologyCoronary angiographyCardiologyAngiographyInternal medicineNuclear medicineMyocardial infarction

Abstract

fetched live from OpenAlex

Objective Randomized comparison between the Tryton Side Branch Stent (Tryton Medical, Durham, NC), used in combination with a main branch drug‐eluting stent (DES), and side branch balloon angioplasty (SBBA, in combination with a main branch DES) using intravascular ultrasound (IVUS), and three‐dimensional quantitative coronary angiography (3D‐QCA). Background The Tryton stent has been developed to improve clinical outcomes after percutaneous coronary intervention (PCI) of bifurcation lesions. Methods We present the pre‐specified IVUS (n = 159) and 3D‐QCA (n = 190) sub‐group analyses of the Tryton coronary bifurcation trial (randomizing Tryton vs. SBBA). Results There were no differences in the main branch with regard to minimal lumen area (MLA) (5.33 ± 1.37 in Tryton vs. 5.69 ± 1.72 mm 2 in SBBA, P = 0.235) with low neo‐intima area in both groups. In the side branch, there were also no statistical significant differences between both groups (3.04 ± 1.02 in Tryton vs. 3.46 ± 1.15 mm 2 in SBBA, P = 0.072). On 3D‐QCA, no differences in minimal lumen diameter (MLD) and percentage diameter stenosis (%DS) were observed in the proximal and distal main branches. In the side branch, there were also no differences found in %DS and MLD (MLD: 1.34 ± 0.043 mm [Tryton] vs. 1.45 ± 0.31 mm [SBBA], P = 0.090). Conclusions There were no differences in 9‐month luminal dimensions of the side branch between the Tryton Stent and Side Branch Balloon Angioplasty, as assessed with IVUS (MLA) and 3D QCA (MLD). Angiographic and ultrasound results of the main branch were not negatively influenced by the Tryton stent. © 2016 Wiley Periodicals, Inc.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.126
Threshold uncertainty score0.519

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.003
Bibliometrics0.0000.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.039
GPT teacher head0.300
Teacher spread0.262 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueCatheterization and Cardiovascular InterventionsSame topicCoronary Interventions and DiagnosticsFrench-language works237,207