MétaCan
Menu
Back to cohort
Record W2434406161 · doi:10.1002/jgh3.12240

Evaluation of lactulose, lactose, and fructose breath testing in clinical practice: A focus on methane

2019· article· en· W2434406161 on OpenAlexaff
Ruth Harvie, Caroline J. Tuck, Michael Schultz

Bibliographic record

VenueJGH Open · 2019
Typearticle
Languageen
FieldMedicine
TopicGastrointestinal motility and disorders
Canadian institutionsKingston General HospitalQueen's University
Fundersnot available
KeywordsLactuloseLactoseBreath testChemistryFructoseMethaneFood scienceCarbohydrateAnimal scienceInternal medicineGastroenterologyBiochemistryMedicineOrganic chemistryBiology

Abstract

fetched live from OpenAlex

Background and Aim Breath testing (BT) is used to identify carbohydrate malabsorption and small intestine bacterial overgrowth. Measuring methane alongside hydrogen is advocated to reduce false‐negative studies, but the variability of methane production is unknown. The aim of this study is to examine the effect of high methane production on hydrogen excretion after ingesting lactulose, fructose, or lactose. Methods A retrospective audit was performed of patients with gastrointestinal symptoms who underwent BT. Following a low fermentable carbohydrate diet for 24‐h, a fasting BT before consuming 35 ml lactulose, 35 g fructose, or lactose in 200 ml water, followed by BT every 10–15 min for up to 3‐h, was performed. A positive test was defined as a ≥20 ppm rise of hydrogen or methane from baseline. A high methane producer had an initial reading of ≥5 ppm. Breath hydrogen and methane production were measured as area under the curve. Chi‐squared tests were used to compare proportions of those meeting the cut‐off criteria. Results Of patients, 26% (28/106) were high methane producers at their initial lactulose test. The test–retest repeatability of methane production was high, with the same methane production status before ingesting lactose in all (70/70) and before ingesting fructose in most (71/73). Methane production was highly variable during testing, with 38% (10/26) having ≥1 reading lower than baseline. Hydrogen produced by high or low methane producers did not differ (1528 [960–3645] ppm min vs 2375 [1810–3195] ppm min [ P = 0.11]). Symptoms and breath test results were not positively related. Conclusion The validity of including an increase of ≥20 ppm methane to identify carbohydrate malabsorption or small intestine bacterial overgrowth should be questioned due to the variability of readings during testing.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.019
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.185
Threshold uncertainty score0.989

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0050.019
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.138
GPT teacher head0.450
Teacher spread0.312 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations18
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueJGH OpenSame topicGastrointestinal motility and disordersFrench-language works237,207