Methods, units and quality requirements for the analysis of haemoglobin A<sub>1c</sub>in diabetes mellitus

2016· review· en· W2460170583 on OpenAlexaboutno aff
Ilkka Penttilä, Karri Penttilä, Päivi Holm, Harri Laitinen, Päivi Ranta, Jukka Törrönen, Rainer Rauramaa

Bibliographic record

VenueWorld Journal of Methodology · 2016
Typereview
Languageen
FieldMedicine
TopicDiabetes Management and Research
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineDiabetes mellitusChromatographyStandardizationGlycationChemistryEndocrinologyComputer science

Abstract

fetched live from OpenAlex

The formation of glycohemoglobin, especially the hemoglobin A1c (HbA1c) fraction, occurs when glucose becomes coupled with the amino acid valine in the β-chain of Hb; this reaction is dependent on the plasma concentration of glucose. Since the early 1970s it has been known that diabetics display higher values OF HbA1C because they have elevated blood glucose concentrations. Thus HbA1c has acquired a very important role in the treatment and diagnosis of diabetes mellitus. After the introduction of the first quantitative measurement OF HbA1C, numerous methods for glycohemoglobin have been introduced with different assay principles: From a simple mini-column technique to the very accurate automated high-pressure chromatography and lastly to many automated immunochemical or enzymatic assays. In early days, the results of the quality control reports for HbA1c varied extensively between laboratories, therefore in United States and Canada working groups (WG) of the Diabetes Controls and Complications Trial (DCCT) were set up to standardize the HbA1c assays against the DCCT/National Glycohemoglobin Standardization Program reference method based on liquid chromatography. In the 1990s, the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) appointed a new WG to plan a reference preparation and method for the HBA1c measurement. When the reference procedures were established, in 2004 IFCC recommended that all manufacturers for equipment used in HbA1c assays should calibrate their methods to their proposals. This led to an improvement in the coefficient of variation (CV%) associated with the assay. In this review, we describe the glycation of Hb, methods, standardization of the HbA1c assays, analytical problems, problems with the units in which HbA1c values are expressed, reference values, quality control aspects, target requirements for HbA1c, and the relationship of the plasma glucose values to HbA1c concentrations. We also note that the acceptance of the mmol/mol system for HbA1c as recommended by IFCC, i.e., the new unit and reference ranges, are becoming only slowly accepted outside of Europe where it seems that expressing HbA1c values either only in per cent units or with parallel reporting of percent and mmol/mol will continue. We believe that these issues should be resolved in the future and that it would avoid confusion if mmol/mol unit for HbA1c were to gain worldwide acceptance.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.043
metaresearch head score (Gemma)0.008
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.980
Threshold uncertainty score0.985

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0430.008
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0050.001
Bibliometrics0.0030.003
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.474
GPT teacher head0.542
Teacher spread0.068 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designOther design
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations20
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueWorld Journal of MethodologySame topicDiabetes Management and ResearchFrench-language works237,207