MétaCan
Menu
Back to cohort
Record W2461700580 · doi:10.1118/1.4958213

TH‐CD‐207B‐07: Noise Modeling of Single Photon Avalanche Diode (SPAD) for Photon Counting CT Applications

2016· article· en· W2461700580 on OpenAlexaff
Xiaobing Zheng, M. Jamal Deen, Hao Peng

Bibliographic record

VenueMedical Physics · 2016
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsMcMaster University
Fundersnot available
KeywordsSilicon photomultiplierAvalanche photodiodePhoton countingAvalanche diodeSingle-photon avalanche diodeNoise (video)PhotomultiplierMaterials scienceAvalanche breakdownOptoelectronicsBreakdown voltagePhysicsPhotonVoltageCMOSOpticsDetectorScintillatorComputer science

Abstract

fetched live from OpenAlex

Purpose: Silicon photomultiplier (SiPM) has recently emerged as a promising photodetector for biomedical imaging applications. Due to its high multiplication gain (comparable to PMT), fast timing, low cost and compactness, it is considered a good candidate for photon counting CT. Dark noise is a limiting factor which impacts both energy resolution and detection dynamic range. Our goal is to develop a comprehensive model for noise sources for SiPM sensors. Methods: The physical parameters used in this work were based upon a test SPAD fabricated in 130nm CMOS process. The SPAD uses an n+/p‐well junction, which is isolated from the p‐substrate by a deep n‐well junction. Inter‐avalanche time measurement was used to record the time interval between two adjacent avalanche pulses. After collecting 1×106 counts, the histogram was obtained and multiple exponential fitting process was used to extract the lifetime associated with the traps within the bandgap. Results: At room temperature, the breakdown voltage of the SPAD is ∼11.4V and shows a temperature coefficient of 7.7mV/°C. The dark noise of SPAD increases with both the excess biasing voltage and temperature. The primary dark counts from the model were validated against the measurement results. A maximum relative error of 8.7% is observed at 20 °C with an excess voltage of 0.5V. The probabilities of after‐pulsing are found to be dependent of both temperature and excess voltage. With 0.5V excess voltage, the after‐pulsing probability is 63.5% at ‐ 30 °C and drops to ∼6.6% at 40 °C. Conclusion: A comprehensive noise model for SPAD sensor was proposed. The model takes into account of static, dynamic and statistical behavior of SPADs. We believe that this is the first SPAD circuit simulation model that includes the band‐to‐band tunneling dark noise contribution and temporal dependence of the after‐pulsing probability.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.005
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.243
Teacher spread0.229 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced X-ray and CT ImagingFrench-language works237,207