MétaCan
Menu
Back to cohort
Record W2466935751 · doi:10.1118/1.4956636

SU‐F‐T‐451: Doses to Organs‐At‐Risk in the Presence and Absence of a 1.5 T Magnetic Field for NSCLC Patients Undergoing SABR

2016· article· en· W2466935751 on OpenAlexaff
Shahad Al-Ward, A Kim, Claire McCann, Mark Ruschin, Patrick Cheung, Arjun Sahgal, Brian Keller

Bibliographic record

VenueMedical Physics · 2016
Typearticle
Languageen
FieldMedicine
TopicRadiomics and Machine Learning in Medical Imaging
Canadian institutionsHealth Sciences CentreSunnybrook Health Science Centre
Fundersnot available
KeywordsSABR volatility modelNuclear medicineRadiation treatment planningField sizeMedicineDosimetryRadiation therapyPhysicsMathematicsRadiology

Abstract

fetched live from OpenAlex

Purpose: To determine whether the electron return effect (ERE) has deleterious effects on lung SABR plans optimized in the presence of an orthogonal 1.5 T magnetic field. Methods: Data from five NSCLC‐SABR patients were used. The Dose was modeled with a 2.5 mm dose grid in the presence and absence of a magnetic field using the Monaco (Elekta) TPS with the Monte Carlo GPUMCD (v5.1) algorithm. For each patient, two plans were generated, one using our conventional Elekta Agility linac beam model and another using the Elekta MRI Linac (MRL) model. Both plans were generated on the average CT using similar dose constraints and a 5 mm PTV. The optimization was performed using our clinic's planning criteria, with normalization of the targets such that their V99% was equal to 99%. The OAR DVHs were compared for each patient. Results: The DVH plots revealed that there were limited differences when optimizing plans in the presence or absence of the magnetic field. The mean of the absolute differences, between the two planning types, in the equivalent uniform doses (EUDs) for the OARs were: 0.3 Gy (range of 0.0 ‐ 1.0 Gy) for the esophagus, 0.6 Gy (range of 0.1 – 1.9 Gy) for the heart, 0.5 Gy (range of 0.2 – 0.8 Gy) for the lungs, and 0.6 Gy (range of 0.2 – 1.5 Gy) for the spinal canal. Regarding the maximum doses to the serial organs, the mean of the differences were 3.0 Gy (esophagus) and 0.9 Gy (spinal canal). No trends in the differences were observed. Conclusion: This study has demonstrated that there were no major differences between plans optimized using a conventional linac and those optimized using an MRI linac with an orthogonal 1.5 T magnetic field. This is attributed to the consideration of the ERE in the optimization. This project was made possible with the financial support of Elekta

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.274
Teacher spread0.266 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicRadiomics and Machine Learning in Medical ImagingFrench-language works237,207