MétaCan
Menu
Back to cohort
Record W2476548567 · doi:10.1111/apt.13757

Proactive therapeutic drug monitoring of infliximab: a comparative study of a new point‐of‐care quantitative test with two established <scp>ELISA</scp> assays

2016· article· en· W2476548567 on OpenAlexaff
Joana Afonso, Susana Lopes, Raquel Gonçalves, Paulo Caldeira, Paula Lago, Helena Tavares de Sousa, Jaime Ramos, Ana Rita Gonçalves, Paula Ministro, Isadora Rosa, Ana Vieira, Cláudia Camila Dias, Fernando Magro

Bibliographic record

VenueAlimentary Pharmacology & Therapeutics · 2016
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicInflammatory Bowel Disease
Canadian institutionsDiscovery Centre
FundersMerck Sharp and Dohme
KeywordsMedicineInfliximabPoint of careDosingTherapeutic drug monitoringIntraclass correlationDrugPoint-of-care testingTurnaround timePharmacologyInternal medicineImmunologyPathologyDisease

Abstract

fetched live from OpenAlex

BACKGROUND: Therapeutic drug monitoring is a powerful strategy known to improve the clinical outcomes and to optimise the healthcare resources in the treatment of autoimmune diseases. Currently, most of the methods commercially available for the quantification of infliximab (IFX) are ELISA-based, with a turnaround time of approximately 8 h, and delaying the target dosage adjustment to the following infusion. AIM: To validate the first point-of-care IFX quantification device available in the market - the Quantum Blue Infliximab assay (Buhlmann, Schonenbuch, Switzerland) - by comparing it with two well-established methods. METHODS: The three methods were used to assay the IFX concentration of spiked samples and of the serum of 299 inflammatory bowel diseases (IBD) patients undergoing IFX therapy. RESULTS: The point-of-care assay had an average IFX recovery of 92%, being the most precise among the tested methods. The Intraclass Correlation Coefficients of the point-of-care IFX assay vs. the two ELISA-based established methods were 0.889 and 0.939. Moreover, the accuracy of the point-of-care IFX compared with each of the two reference methods was 77% and 83%, and the kappa statistics revealed a substantial agreement (0.648 and 0.738). CONCLUSIONS: The Quantum Blue IFX assay can successfully replace the commonly used ELISA-based IFX quantification kits. This point-of-care IFX assay is able to deliver the results within 15 min makes it ideal for an immediate target concentration adjusted dosing. Moreover, it is a user-friendly desktop device that does not require specific laboratory facilities or highly specialised personnel.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.014
metaresearch head score (Gemma)0.016
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.014
Threshold uncertainty score0.073

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0140.016
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.001
Science and technology studies0.0000.001
Scholarly communication0.0020.001
Open science0.0010.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.333
Teacher spread0.302 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations60
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueAlimentary Pharmacology & TherapeuticsSame topicInflammatory Bowel DiseaseFrench-language works237,207