MétaCan
Menu
Back to cohort
Record W2501051861

Ultrasound-Guided Genicular Nerve Pulsed Radiofrequency Treatment For Painful Knee Osteoarthritis: A Preliminary Report.

2016· article· en· W2501051861 on OpenAlexaboutno aff
Serdar Kesikburun, Evren Yaşar, Ayça Uran, Emre Adıgüzel, Bilge Yılmaz

Bibliographic record

VenuePubMed · 2016
Typearticle
Languageen
FieldEngineering
TopicUltrasound and Hyperthermia Applications
Canadian institutionsnot available
Fundersnot available
KeywordsMedicinePulsed radiofrequencyWOMACOsteoarthritisVisual analogue scaleSurgeryKnee painNerve blockInterventional pain managementPopulationChronic painPhysical therapyPain reliefPathology
DOInot available

Abstract

fetched live from OpenAlex

BACKGROUND: Genicular nerve ablation with radiofrequency (RF) has recently emerged as a promising treatment in the management of osteoarthritis related knee pain. To date, genicular nerve injections have been performed under fluoroscopic guidance. OBJECTIVE: To evaluate the effect of ultrasound-guided genicular nerve pulsed RF treatment on chronic knee pain and function in patients with knee osteoarthritis. STUDY DESIGN: Single-arm prospective study. SETTING: University hospital and rehabilitation center in Turkey. METHODS: A review was made of 29 patients with medial knee osteoarthritis who had undergone genicular nerve block in the previous 6 months. Patients with at least 50% reduction in the visual analog scale (VAS) score after genicular nerve block and with no on-going pain relief were selected for the study. Ultrasound-guided genicular nerve pulsed RF was applied to 15 knees of 9 patients. Pain and knee function were assessed with 100-mm VAS and Western Ontario and McMaster Universities (WOMAC) index throughout 3 months. RESULTS: A significant reduction in VAS scores was detected over time after the pulsed RF procedure (f: 69.24, P < 0.01). There was a significant improvement in the WOMAC scores (f: 539.68 , P < 0.01). LIMITATIONS: The small number of participants, the lack of a control group, and short follow-up period were limitations of the study. CONCLUSIONS: Genicular nerve pulsed RF treatment has been found to be safe and beneficial in osteoarthritis related knee pain. Further studies with a larger population and randomized controlled study design are warranted to confirm the positive findings of this preliminary report.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.948
Threshold uncertainty score0.772

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.213
Teacher spread0.194 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations29
Published2016
Admission routes1
Has abstractyes

Explore more

Same venuePubMedSame topicUltrasound and Hyperthermia ApplicationsFrench-language works237,207